11
DEC 2021
INSTALL GUIDE
1
INSTALLATION
COGNEX DataMan 374
REV 00
NOTE:
S1
Set toggle switch to ‘
Normal
’ for single and multiple readers.
S2
Set toggle switch to ‘
Default
’ for a single reader, and ‘
All On
’ for
multiple readers.
J10, J11
A0117569 (XE169) or 9100703Y and 9100720R (C167)
J31
Collate/OMR Folder 9105223G and Insert Feeder, Track 9107507L
Toggle Switch S1 must be set to ‘
NORMAL
’ for both single and
multiple Cognex Readers setups. Toggle switch S2 must be set to
‘
DEFAULT
’ for single and ‘
ALL ON
’ for multiple Cognex Readers as
shown in Figure 1.22.
1.5
CONNECTING THE READER TO THE IMOS PC
The DS1200 M/C can be fitted with either a single reader or multiple readers.
Single Reader
If a single reader is fitted, the USB/Ethernet Adapter (A0014392) can be plugged
directly into an available USB port (Front/Back) on the IMOS PC.
Multiple Readers
If multiple readers are fitted, the following Multi-Reader Kit is available to order:
▪
A0135969 DataMan Viewer Kit (Max. 4 Readers per kit)
Figure 1.21 shows the parts required to connect a Cognex DataMan 374 to the IMOS PC
allowing the viewing of images in the Reader Setup Screen within IMOS.
QTL-RND-OPS-00000324-A-00
Figure 1.21 – Cognex DataMan 374 connection parts
To connect a single reader or multiple readers, first route the RJ45/Ethernet cable
supplied with the reader kit, from the reader through the DS-1200 machine following
the details set out in section
.