Connect the Ethernet Cable
CAUTION
:
The Ethernet cable shield must be grounded at the far end.
Whatever this cable is plugged into (usually a switch or router) should have a
grounded Ethernet connector. A digital voltmeter should be used to validate
the grounding. If the far end device is not grounded, a ground wire should be
added in compliance with local electrical codes.
1.
Connect the Ethernet cable's M12 connector to the DataMan system's
ENET connector.
2.
Connect the Ethernet cable's RJ-45 connector to a switch/router or PC, as
applicable.
Connect the Breakout Cable
CAUTION
:
To reduce emissions, connect the far end of the Breakout cable
shield to frame ground.
Note
:
l
I/O wiring or adjustments to I/O devices should be performed when
the reader is not receiving power.
l
You can clip unused wires short or use a tie made of non-conductive
material to tie them back.Keep bare wires separated from the +24
VDC wire.
1.
Verify that the 24 VDC power supply is unplugged and not receiving power.
2.
Attach the Breakout cable's +24 VDC and Ground to the corresponding
terminals on the power supply.
19