Discrete I/O
operating
Limits
HS Output 0, 1, 2, 3
I
MAX
@ 24 VDC
50 mA
R
MAX
@ 12 VDC
150 Ω
@ 24 VDC
470 Ω
Input 0 (Trigger)
V
IH
±15 — ±25 V
Input 1
V
IL
0 — ±5 V
I
TYP
@ 12 VDC
2.0 mA
@ 24 VDC
4.2 mA
Power Supply
Requirements
l
PoE powered: Class 1 PoE supply, maximum 3.84 W, or
l
External power supply (no PoE): +24 VDC +/- 10% (1 A maximum, 5 W average)
Supplied by LPS or NEC class 2 only
Power
Consumption
<3.84 W (PoE Class 1)
<5 W (average, externally powered at +24 V)
DataMan 260 Series Imager Specifications
Specification
DataMan 260 Imager
DataMan 262 Imager
Image Sensor
1/3 inch CMOS
1/3 inch CMOS
Image Sensor
Properties
4.51 mm x 2.88 mm (W x H), 6.0 μm
square pixels
4.8 mm x 3.6 mm (W x H), 3.75 μm square
pixels
Image Resolution
(pixels)
752 x 480
1280 x 960
28