31
Appendix B
B.1
Configuring the Expansion Module using In-Sight PC Host
As mentioned in Section 2.6, before the 1460 I/O Expansion Module can be used, the
In-Sight sensor’s settings must be configured to recognize the availability of the additional
inputs and outputs, as well as the added serial hardware handshake capability. The 1460 I/O
Expansion Module may be configured using the In-Sight PC Host software.
1.
Physically connect the 1460 I/O Expansion Module to the In-Sight sensor, as described in
Section 2.5.
2.
Open the In-Sight PC Host program and log on to the sensor.
3.
Open the System menu (Figure B-1) and select Settings to open the Settings menu (Figure
B-2).
Figure B-1: System menu (In-Sight PC Host)