Installation
12
Figure 2-8: Discrete Output Settings (In-Sight Explorer)
6.
Select OK to save the new settings to the sensor’s flash RAM.
The sensor can also be configured to use the 1460 I/O Expansion Module by opening the
Discrete Input dialog and following step 4, as described above.
Once the 1460 I/O Expansion Module is selected in either the Discrete Input or Discrete
Output dialogs, it is automatically enabled for both inputs and outputs, and hardware hand-
shaking may be used in serial communications.
NOTE
When an existing .JOB file containing a WriteDiscrete function is loaded on an In-Sight
sensor to which the I/O Expansion Module has just been added, the Start Bit and Number
of Bits parameters in WriteDiscrete must be changed to reflect the new configuration of the
I/O lines. For example, the physical output lines 0 and 1 become lines 8 and 9 (HSOUT 0
and HSOUT 1) when the I/O Expansion Module is enabled.
NOTE
An error message will appear if the I/O Expansion Module is not attached to the In-Sight
sensor, and the Discrete Output dialog will return to its default configuration. Verify that the
I/O Expansion Module is connected as described in Section 2.5, then repeat steps 3 - 6.
Summary of Contents for 800-5815-1
Page 1: ......
Page 2: ......
Page 6: ...iv ...
Page 10: ...List of Figures viii ...
Page 12: ...List of Tables x ...
Page 16: ...Introduction 4 ...
Page 48: ...36 ...
Page 50: ...38 C 1 1 1460 I O Expansion Module Output to PLC Input ...
Page 52: ...40 C 1 3 1460 I O Expansion Module Output to Pilot Light Input ...
Page 54: ...42 C 1 5 1460 I O Expansion Module Input to PLC Output ...
Page 56: ......
Page 57: ... Q 6LJKW 0RGHO 2 SDQVLRQ 0RGXOH QVWDOODWLRQ DQG 5HIHUHQFH www cognex com 597 0029 02 ...