rning on the BlueCheck Capture Device

Getting Started  - Cogent Systems, Inc. Proprietary Information 

19

 

Turning on the BlueCheck Capture Device

To turn on the 

BlueCheck

 capture device, hold down the 

On/Off

 button 

until the 

BlueCheck

 device turns on. The 

Power Indicator 

will turn red, 

and the 

L I V E   C A PT U R E

 message will be displayed on the 

Display Panel

In addition, the 

Bluetooth

 

Connection Indicator

 will turn solid blue 

when the device has connected to 

MobileID

. You will not be able to send 

any captured fingerprint images to 

MobileID

 until the 

Bluetooth

 

Connection Indicator

 has turned solid blue. For more information about 

connecting your device to 

MobileID

 via 

Bluetooth

, contact your System 

Administrator.

Note: If the 

BlueCheck

 

device is turned on before launching the 

MobileID 

application, it may take up to 20 seconds to establish a 

Bluetooth 

connection after the application is started.

Calibrating the BlueCheck Capture Device

If the 

BlueCheck

 capture device requires calibration (e.g., it is being 

used for the first time), follow these steps:

1

Ensure that the 

BlueCheck

 capture device is turned on. For instructions 

on turning on the 

BlueCheck

 capture device, please refer the previous 

section.

2

Press the 

Blue

 button (located above 

NEXT

 on the 

Display Panel

). The 

message 

C A L I B R AT E

 will be displayed on the 

Display Panel

.

Note: If desired, you may exit from the calibration procedure at this point by 
pressing the 

Blue

 

button (located above 

NEXT 

on the 

Display Panel

).

3

Press the 

Green

 button (located above 

OK

 on the 

Display Panel

). The 

message 

C a l i b r a t i n g . . .

 will be displayed on the 

Display Panel

. After 

approximately 5-10 seconds, the 

S u c c e s s  

message will be displayed 

momentarily on the 

Display Panel

. The 

C A L I B R AT E

 message will be 

redisplayed on the 

Display Panel

, and the calibration procedure will be 

complete.

Summary of Contents for BlueCheck

Page 1: ...s document may be reproduced transmitted stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic optical chemical manu...

Page 2: ...Document Revision History Document Version Date Comments 1 0 05 10 2006 Initial draft written 1 1 08 09 2006 Updated to include the new BlueCheck fingerprint capture device...

Page 3: ...etooth Enabled Devices 9 Chapter 4 Getting Started 17 Logging In 17 Turning on the BlueCheck Capture Device 19 Calibrating the BlueCheck Capture Device 19 Chapter 5 Performing a Quick Search Identific...

Page 4: ......

Page 5: ...easily perform in the field fingerprint identifications You can simply have a subject place his her finger onto a fingerprint capture device for fast and easy identification The software provides you...

Page 6: ...es can be wirelessly transferred to the MobileID Pocket PC PDA for NIST packaging and submission to LAFIS over a wireless network Submissions and responses are sent and received via standard wireless...

Page 7: ...fingerprint Green Button Used to begin the fingerprint capture process and to indicate missing bandaged fingers On Off Button Used to turn the BlueCheck device on and off Blue Button Used to cancel t...

Page 8: ...most completely depleted Immediate re charg ing is required Bluetooth Connection Indicator The Bluetooth Connection Indicator will display one of the following When the Bluetooth Connection Indicator...

Page 9: ...lue button when the LIVE CAPTURE message is displayed to select NEXT and calibrate the device For more instructions on calibrating the device please refer to Calibrat ing the BlueCheck Capture Device...

Page 10: ...AFIS over a wireless network Figure 1 3 Pocket PC PDA The specifications for the Pocket PC PDA are Processor 416 Mhz Intel PXA270 Memory 64 MB RAM 128 MB Flash ROM Operating System Microsoft Windows M...

Page 11: ...CAFIS matches prints by comparing the attribute maps of each of the prints stored in the database with the attribute map of the search print and assigns them a score that ranks the degree of similari...

Page 12: ...8 Key Terms Cogent Systems Inc Proprietary Information Notes...

Page 13: ...established trusted pair each device automatically accepts communication bypassing the discovery and authentication process that normally happen during Bluetooth interactions Pairing the Bluetooth Ena...

Page 14: ...ry Figure 3 1 Settings Window 3 Tap the Connections tab The Connections subwindow will be displayed an example of which is shown in Figure 3 2 Figure 3 2 Connections Subwindow 4 Double tap on the Blue...

Page 15: ...rs only Cogent Systems Inc Proprietary Information 11 Figure 3 3 Bluetooth Subwindow 5 Ensure that the Turn on Bluetooth checkbox is selected 6 Tap the Devices tab The Bluetooth Devices subwindow will...

Page 16: ...ve OK on the Display Panel The Bluetooth Connection indicator will display a blinking blue light the Power Indicator will display a blinking red light and the PAIRING message will be displayed on the...

Page 17: ...ogent Systems Inc Proprietary Information 13 Figure 3 6 Enter Passkey Subwindow 13 Enter the passkey in the Passkey field Note The default passkey is 1234 14 Tap Next The Partnership Settings subwindo...

Page 18: ...ish The Bluetooth Devices subwindow will be displayed an example of which is shown in Figure 3 8 Figure 3 8 Bluetooth Devices Subwindow 17 Tap the Keyboard icon located on the bottom portion of the wi...

Page 19: ...n 15 Figure 3 9 Bluetooth COM Ports Subwindow 19 Tap New Outgoing Port The Add a Device subwindow will be displayed an example of which is shown in Figure 3 10 Figure 3 10 Add a Device Subwindow 20 En...

Page 20: ...rt drop down menu 23 Tap Finish The BlueCheck capture device has now been paired to the Pocket PC PDA The Bluetooth COM Ports subwindow will be displayed an example of which is shown in Figure 3 12 Fi...

Page 21: ...se steps 1 Use the stylus to tap on the Start button located on the top left corner of the Pocket PC PDA screen A drop down menu will be displayed 2 Select MobileIDHost from the drop down menu The Log...

Page 22: ...n example of which is shown in Figure 4 2 Figure 4 2 MobileID Main Menu Window Note From the MobileID Main Menu window you can choose whether to perform a quick search identification IDN Quick Search...

Page 23: ...ke up to 20 seconds to establish a Bluetooth connection after the application is started Calibrating the BlueCheck Capture Device If the BlueCheck capture device requires calibration e g it is being u...

Page 24: ...20 Getting Started Cogent Systems Inc Proprietary Information Notes...

Page 25: ...he Pocket PC PDA Note Your MobileID system may be configured to capture thumbprints or a different pair of fingers In the following description the procedure for capturing a subject s thumbprints is u...

Page 26: ...tons are used to select menu options from the Display Panel during the fingerprint capture procedure For more information about BlueCheck menu options please refer to BlueCheck Menu Options on page 5...

Page 27: ...e one of the following actions If the right thumb is missing damaged press the Green button located above MIS on the Display Panel If the right thumb is not missing damaged have the subject place his...

Page 28: ...ing damaged take one of the following actions If the left thumb is missing damaged press the Green button located above MIS on the Display Panel If the left thumb is not missing damaged have the subje...

Page 29: ...idates with scores below the designated threshold are found on LAFIS the message No hit will be displayed on the Display Panel of the BlueCheck capture device The results of the LAFIS search are displ...

Page 30: ...Quick Search Identification Cogent Systems Inc Proprietary Information 9 To return to the MobileID Main Menu window tap Exit A dialog box will be displayed 10 Tap Yes The MobileID Main Menu window wi...

Page 31: ...PC PDA Note Your MobileID system may be configured to capture thumbprints or a different pair of fingers In the following description the procedure for capturing a subject s thumbprints is used as an...

Page 32: ...s are used to select menu options from the Display Panel during the fingerprint capture procedure For more information about BlueCheck menu options please refer to BlueCheck Menu Options on page 5 3 W...

Page 33: ...of the following actions If the right thumb is missing damaged press the Green button located above MIS on the Display Panel If the right thumb is not missing damaged have the subject place his her r...

Page 34: ...maged take one of the following actions If the left thumb is missing damaged press the Green button located above MIS on the Display Panel If the left thumb is not missing damaged have the subject pla...

Page 35: ...subwindows the required fields for your agency are indicated in yellow 11 Tap the Demo button located on the top of the Transaction Queue window The Demographics data entry subwindow will be displaye...

Page 36: ...ugshot capture window will become active 15 Rotate the Pocket PC PDA to the left and position the PDA camera so that the subject s face is centered in the mugshot capture window 16 Press the camera bu...

Page 37: ...Mugshot Photo 19 After you have finished capturing the mugshot photo you may send the transaction to LAFIS 20 If a possible hit against the tenprint database is found on LAFIS the BlueCheck device wi...

Page 38: ...left of the transaction number In addition the subject s name will be displayed in the Status column A Non Hit will be indicated by a green square to the left of the transaction number In addition No...

Page 39: ...nsaction in the Transaction Queue window by simply highlighting the transaction in the queue and tapping the View button When you do so the Transaction View window will be displayed for that transacti...

Page 40: ...the subject s Hit No Hit status and identity if available will be displayed An example is shown in Figure 7 2 Figure 7 2 View the Identification Information Returned by LAFIS Viewing the Demographic I...

Page 41: ...7 3 View the Demographic Information Submitted to LAFIS Viewing the Prints Submitted to LAFIS From the Transaction View window tap the Prints button The fingerprints submitted or waiting to be submit...

Page 42: ...utton LAFIS s response to the identification request will be displayed An example is shown in Figure 7 5 Figure 7 5 View LAFIS s Response to the Identification Request Viewing the Mugshot Photo Submit...

Page 43: ...Viewing Transaction Information Cogent Systems Inc Proprietary Information 39 Figure 7 6 View the Mugshot Photo Submitted to LAFIS Returning to the Transaction Queue Window To return to the Transactio...

Page 44: ...40 Viewing Transaction Information Cogent Systems Inc Proprietary Information Notes...

Page 45: ...llow these steps 1 Tap the Exit button A dialog box will be displayed 2 Tap the Yes button The MobileID Main Menu window will be displayed 3 Tap the Exit button A dialog box will be displayed 4 Tap th...

Page 46: ...42 Logging Out Cogent Systems Inc Proprietary Information Notes...

Page 47: ...lus to tap on the Start button located on the top left corner of the Pocket PC PDA screen A drop down menu will be displayed 2 Select MIDConfigure from the drop down menu The MobileID Host Configurati...

Page 48: ...access password is qwerty 4 Tap Login The configuration information for MobileID will be displayed An example is shown in Figure A 2 Figure A 2 MobileID Host Configuration 5 Tap User Management Passwo...

Page 49: ...new user password in the second field below the User Management Passwords portion of the window 6c Enter the new user password again in the third field below the User Management Passwords portion of t...

Page 50: ...Figure A 5 MobileID Host Configuration 6g Tap the Save button The MobileID Host Configuration window is displayed an example of which is shown in Figure A 6 Figure A 6 MobileID Host Configuration Win...

Reviews: