lamp access

To gain access to the lamp, undo the locking mechanism at the
top of the 

sequenza 500 al 

and by using a plane screwdriver,

turn clockwise the security screw. The hinged front of the unit
will open, together with the safety glass, allowing complete
access to the lamp.
Insert the lamp into the double-ended lampbase. Should you
encounter any difficulty during this operation, DO NOT USE
UNDUE FORCE. Check all components and repeat the procedure.

closing the unit

Carefully close the front of the 

sequenza 500 al

. A sudden jar-

ring impact may cause damage to the lamp filament or fixture.
After installing the lamp reverse the procedure above to secure
the hinged front

3. Installation

Mounting the yoke

Locate, in the packaging, the “L”-shaped yoke, the M5 bolt, the
graduated fixing plate, and the T-handle.
Assemble the yoke prior to mounting it to the housing. Slide the
threaded M8 end of the T-handle through the untapped hole of
the yoke (placing the smooth washer between yoke and T-hand-
le), and affix the graduated fixing plate so that the markings are
to the exterior, adjacent to the yoke. Open the front inspection
lid of the 

sequenza 500 al

and insert the M5 bolt in the lateral

slot on the yoke fixing side. Now slide the yoke onto the guide
located on the external side of the 

sequenza 500 al

and con-

nect and tighten the bolt to the yoke with a screwdriver. This
tightening will result in the yoke sliding along its guide and sea-
ting itself correctly. Do not use undue force in this operation.

assembling multiple units

This procedure is similar to that of mounting the yoke. Open the
front inspection lid of the 

sequenza 500 al

and insert the M5

bolt into the lateral slot on the side of one of the 

sequenza

500 al

to be joined. Slide the accessory joining piece (

coemar

cod. 5086

) onto the guide, then connect and tighten the bolt. 

This tightening will result in the joining piece sliding along the guide
and seating itself correctly. Do not use undue force in this operation.
You can now connect the 

sequenza 500 al

units together.

Safety glass

The 

sequenza 500 al

has a tempered safety glass fitted as stan-

dard. This is useful in case a lamp ruptures, averting the risk of hot,
falling glass. If necessary, it is possible to remove the safety glass by
means of removing the 4 screws which fix  the front housing.

mounting accessories

Each 

sequenza 500 al

is supplied with a colour frame which

has one serrated edge and which fits into the front housing. The
serrated edge may be place to the top or to the bottom of the
fixture, however is desired. The 

sequenza 500 al

also has avai-

lable an accessory barndoor  which fits to the front of the unit.

Summary of Contents for sequenza 500 al 5090

Page 1: ...1 edizione ottobre 1996 sequenza 500 al manuale di istruzioni instruction manual 1st edition october 1996 ...

Page 2: ...ce information of the model and the retailer from whom you purchased your sequenza 500 al This information will assist us in providing spare parts repairs or in answering any technical enquiries with the utmost speed and accuracy WARNING the security of the fixture is granted only if these instructions are strictly fol lowed therefore it is absolutely necessary to keep this manual 290 mm 260 mm 30...

Page 3: ...Index 1 Packaging 2 Lamp installation and replacement 3 Installation 4 Electrical connection 5 Operation 6 Maintenance 7 Electrical schematic 8 Spare parts coemar authorised service centres worldwide ...

Page 4: ...complete with safety glass 1 colour frame 1 L shaped yoke 1 graduated fixing plate complete with bolts and T handle 2 Lamp Installation lamp type and maintenance sequenza 500 al uses a linear halogen lamp of either 300 or 500W The following lamps are available through the coemar distribu tor network coemar cod 105008 power 300 w voltage 240 v luminous flux 5 000 lm colour temperature 3000 K base R...

Page 5: ...e the yoke onto the guide located on the external side of the sequenza 500 al and con nect and tighten the bolt to the yoke with a screwdriver This tightening will result in the yoke sliding along its guide and sea ting itself correctly Do not use undue force in this operation assembling multiple units This procedure is similar to that of mounting the yoke Open the front inspection lid of the sequ...

Page 6: ...ight of the unit s installation The sequenza 500 al is designed for internal use in ambient temperatures below 40 C safety chain The use of a safety chain coemar cod 069 affixed to the sequenza 500 al and to the primary suspension point is highly recommended in the case however unlikely that the suspension point should fail The rear of the fixture is provided with a robust ring as an attachement p...

Page 7: ...of the lamp protection The use of a fuse rated at 2 A for a 300w lamp and 4 A for a 500w lamp or the use of a thermal magnetic circuit breaker for each sequenza 500 al is highly recommended Should the sequenza 500 al be operated via a dimming system ensure that the dimmer is fitted with fused load protec tion 5 Operation focusing Whilst focusing the unit it is recommended that any colour gel be re...

Page 8: ...performing this type of maintenance are a brush and a common vacuum cleaner or an air compressor lamp The lamp should be replaced if there is any observable damage or deformation due to heat This will avoid the danger of the lamp exploding electrical components Check all components for correct earth connection and the pro per attachment of all connectors refastening if necessary mechanical compone...

Page 9: ...serves the right to effect modifications without notification instruction manual sequenza 500 al 1st edition october 1996 coemar spa viaInghilterra 46042Castelgoffredo Mantova Italy Tel 0376 77521 Fax0376 780657 ...

Reviews: