7.
Press the
+
or
-
buttons until
CL L
is displayed (to access the lamp life counter for the left lamp) and press
enter
.
8.
The display will show
SURE
.
Confirm this by pressing enter.
9.
To exit calibration mode, press the
+
or
-
button until
END
is displayed. Confirm this by pressing
enter.
N.B.
In the
HOUR
section of the
MEAS
menu, you may confirm that the
LIFE
values have been reset, whilst the other measures
LIFS
(total lamp life) and
UNIT
(projector life) remain unaltered.
All the components of the
Panorama Power MK2
are available as replacement spares from your authorisded
Coemar
service centre.
Accurate description of the fixture, model number, and type will assist us in providing for your requirements in an efficient and effective
manner.
Panorama Power MK2 is protected by various international patents which prohibit copying of the unit in total
or in part.
SNER
: SYNCHRONISATION
Error
Check and possibly replace the U9 opto-isolator.
EPER
: EEPROM
Error
The EEPROM is either defective or absent; refer to your coemar service centre for a replacement component.
DTER
: DATA Error
The initial parameter settings are incorrect or corrupt; the projector has reloaded its factory default settings. Turn
the projector off and on again. Should the error reoccur, refer the unit to your authorised coemar service centre
to have the EEPROM check and possibly replaced.
ADER
:
DMX ADDRESS Error
The projector is not receiving all DMX channels needed to operate correctly. Check the DMX address indicated on
the display and the channel numbers being outputted from the controller. Note that not all controllers will output
all 512 channels.
ER20
÷
ER99
: SYSTEM Error
Turn the unit off and on again. If the error persists, contact your authorised coemar service centre.
The following table outlines various problems and their possible solutions.
Problem
Possible solution
Panorama Power MK2
will not turn on
Panorama Power MK2
does not have mains power:
- Check that the mains power cable is connected to power.
- Check the input voltage
.
-
Check and replace the fuse if necessary.
Panorama Power MK2
does not respond to DMX signal. DMX may not be being recieved by the
Panorama Power MK2
:
- Check controller output and all DMX cables
.
- Check the display panel to ensure that no function which inhibits
DMX control has been selected.
- Panorama Power MK2
may have an incorrect DMX address: Check
the unit’s DMX address.
The
Panorama Power MK2
has been set to MASTER but
is not running any programs
- Check that no other projector in the series has been designated as a
MASTER.
- Check that there is no incoming
DMX
signal (a conflict will occur with
MASTER signals and DMX signal).
15. Frequently asked questions
14. Error messages
13. Patents
12. Spare parts
28