Coemar Manual System 6 Plus Instruction Manual Download Page 8

If the DMX 512 fixture to be controlled from the 

manual system 6 

has an XLR3 connector, simply do not connect pins 4

and 5, which are internationally recognised as not in use for DMX 512 signal connection.

The following diagram shows DMX 512 connection between a 

manual system 6

and a 

coemar comet

.

All DMX 512 controllable fixtures and dimmers  must be set to the correct DMX address in order to operate correctly from the

manual system 6.

Section 5 describes the procedure necessary for correct setting of the fixture to be controlled from the 

manual system 6.

in

in

out

out

5 pin XLR 5/M

3 pin XLR 3/F

3

2

1

to other 

comet

dmx 512
standard

out

Summary of Contents for Manual System 6 Plus

Page 1: ...manual system 6 plus manuale di istruzioni intructions manual 1 edizione luglio 1998 1st edition july 1998 ...

Page 2: ...0 10V DMX 512 flash master master 4 3 2 1 flash 6 5 delay time sec 0 16 manual system 6 dmx out 0 5 2 3 5 5 5 7 8 5 9 5 11 5 13 5 15 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 10 ...

Page 3: ... 5 1 coemar DIGIfactor 6 channels 5 2 coemar comet 6 Powering up 6 1 external 20V DC power supply 6 2 power supply from the dimmer 7 Functions 7 1 Adjusting output levels 7 2 Adjusting fade times 7 3 Flash buttons 7 4 Area for writing down channel functions 8 Optional functions 9 Technical characteristics 10 Coemar authorised service centres worldwide ...

Page 4: ...s information will assist us in providing you with prompt and accurate information serial number date of purchase retailer address suburb capital city state tel fax Please note in the space provided above the relative service information of the model and the retailer from whom you purchased your manual system 6 This information will assist us in providing spare parts repairs or in answering any te...

Page 5: ...ply An internal electronic device protects the unit against oversupply The DMX 512 output is electronically controlled Thanks to the rear mounted rubber feet the manual system 6 is easily operated on any desk surface At the rear of the unit are two assembly features which allow the manual system 6 to be operated in the vertical position for example on a wall in cases where installation may necessi...

Page 6: ...C input Pin 8 0V DC If your fixture accepts the coemar standard you may use locking0din cables which are available from your authorised coemar distributor Code 247 5m length Code 248 10m length Code 249 25m length Code 250 50m length Should you wish to order only components the following coemar compnent parts are available ME 261 Locking din plug CV 924 per metre screened cable 8 core Ø 0 25 CV 41...

Page 7: ...fixture is as follows Output signal connection from the XLR5 socket on the manual system 6 Pin 1 Ground GND Pin 2 DATA Pin 3 DATA Pin 4 Optional Pin 5 Optional The following components are available from coemar ME 1344 XLR 3 plug ME 1230 XLR 3 socket ME 4966 XLR 5 plug ME 4965 XLR 5 socket CV 4158 per metre screened cable 2 core Ø 0 5 Connection must be via 2 core screened cable adhering strictly ...

Page 8: ...agram shows DMX 512 connection between a manual system 6 and a coemar comet All DMX 512 controllable fixtures and dimmers must be set to the correct DMX address in order to operate correctly from the manual system 6 Section 5 describes the procedure necessary for correct setting of the fixture to be controlled from the manual system 6 in in out out 5 pin XLR 5 M 3 pin XLR 3 F 3 2 1 to other comet ...

Page 9: ...ed as follows Press the or buttons until the display shows DMX A001 the display will flash indicating that the address is not recor ded 2 Press the enter button to record your selection the display will cease flashing and the fixture will respond to address DMX 1 holding down the or will allow for rapid scrolling through the display 5 2 coemar comet It is important to set the dip switched correctl...

Page 10: ...V 50 60Hz Power reception is indicated by the switching on of the dmx out led which will remain static on for 5 seconds and will then flash whilst it monitors outgoing dmx 512 signal 6 2 power supply from the dimmer Most coemar dimmers manufactured since 1982 will automatically power up the manual system 6 via their analogue con nections Check that your fixture is supplying 20V DC via pin number 7...

Page 11: ...er to be assigned a fade time Adjsut the level of the delay time potentiometer to say 16 seconds delay time sec 0 16 0 5 2 3 5 5 5 7 8 5 9 5 11 5 13 5 15 1 Adjust the level of the master slider from 0 al 100 The leds corresponding to the sliders 1 to 6 will come on at a level of brightness corresponding to the respective levels being outputed At this time the manual system 6 is generating a 0 10 V...

Page 12: ... The delay time potentiometer will operate on the master in both fade up and fade down modes 0 10V DMX 512 master manual system 6 0 10 20 30 40 50 60 70 80 90 100 dmx out 3 Adjust the position of sliders 1 to 6 to achieve the output level which you require The leds corresponding to the sliders 1 to 6 will remain off indica ting that there is no signal being transmitted 4 3 2 1 6 5 0 10 20 30 40 50...

Page 13: ...imum level as determined by the master 4 3 2 1 flash 6 5 4 Adjust the master slider to the required level master 0 10 20 30 40 50 60 70 80 90 100 dmx out 3 Press the flash master button the 6 channels will flash up to the level deternined by the sliders The leds corresponding to the sliders will come on to the level assi ned by the sliders remaining on until the flash master button is relea sed Th...

Page 14: ...n Channel 4 controls colour selection Channel 5 contols black out and strobe functions Channel 6 control dimming halogen lamp versions or lamp on and off facility discharge versions 4 3 2 1 6 5 0 10 20 30 40 50 60 70 80 90 100 10 X Y gobo colour strobo lamp 1 Channel 1 controls black out and strobe functions Channel 2 controls the program being run 10 levels Channel 3 controls mirror speed Channel...

Page 15: ...idge P2 return the controller to its orignal state by replacing all components coemar sets the flash master to its standard position as described in section 7 3 of this manual bridge P2 in in this case is closed over contacts 2 and 3 The function of the flash master button can be altered if bridge P2 is located over contacts 1 and 2 In this case the function is altered as follows In this setting i...

Page 16: ...om 0 1 to 15 seconds Microprocessor controlled digital DMX 512 output via 5 pin XLR5 Analogue 0 10 V DC output via 8 pin Locking din Individual channel bufffer for connection of dimmers in series 6 channels of analogue output variable from 0 to 10V DC 6 channels of digital DMX512 signal addressed 1 to 6 Dust resistant sliders Over voltage supply protection 4 rubber feet on rear FIxings for wall mo...

Page 17: ...erves the right to effect modifications without notification instruction manual manual system 6 plus 1st edition july 1998 coemar spa viaInghilterra 46042Castelgoffredo Mantova Italy Tel 0376 77521 Fax0376 780657 ...

Reviews: