29
9.7
Error messages
If a malfunction occurs,
LEDko FullSpectrum 6 HD
has a self-diagnostic system that will show
the error message on the display. The following table will explain in detail the most common
errors. If, despite of suggested intervention, the problem persists, call the
Coemar
Service
Center.
9.6
Special functions of the fixture
Storing the DMX signal
To use the fixture without an active DMX console it is possible to store the DMX settings in two
ways:
•
Through the
menu
;
• Disconnecting the DMX signal when the fixture is on. When the signal is unconnected the
fixtures stores the signal;
Automatic fan standby
To decrease the noise and the power consumption the cooling fan turns off after 10 minutes of
fixture inactivity.
Error code
Description
Data Error
Data error
Initial data loading has failed the projector loaded the default
data settings: restart the fixture again, and if the error persists
contact the
Coemar
assistance center.
Address Error
Address error
The projector does not receive all channels of DMX needs to
function properly. Check the DMX address indicated on the
display and the number of channels generated by the mixer
control. We recall in this connection that some controllers do
not generate all the 512 channels.
sensor not
detected
Sensor not detected
LED temperature sensor missing or damaged.
sensor shorted
Sensor shorted
Error of the LED’s sensor circuit.
fan not
rotating
Fan not rotating
Auto diagnostic routine found that the Fan may be damaged,
contact Coemar assistance for the module replacement.
IMPORTANT:
To ensure the sensor is giving correct readings
or that the fan rotates correctly, set the fan to the maximum
level.