. Powering up
5.2
Connection to mains power
Mains cable characteristics
The mains cable provided is thermally resistant, complying to the most recent International
standards.
Note:
in case of cable replacement, similar cable with comparable thermal resistant qualities
must be used exclusively (cable 3 X 1,5 ø external 10 mm, rated 300/500V, tested to 2 KV, op-
erating temperature -40°C + 180°C, Coemar cod. CV5311).
Connection to mains power
LEDko FullSpectrum 6
is equipped with two power connectors, one as input and one as out
-
put, which can be used to feed up to 8 (at 230 VAC) or 4 (90 VAC) fixtures.
The max absorption of
LEDko FullSpectrum 6 HD
is reported in the following table:
- 230 VaC 1.06 A constant during normal exercise.
- 90 VaC 2.71 A constant during normal exercise.
5.1
Operating voltage and frequency
The unit may operates at voltages ranges from 90 to 250VaC at a frequency of 50 or 60 Hz. It
is not needed to effect any setup procedures:
LEDko FullSpectrum 6 HD
will automatically
adjust its operation to suit any frequency or voltage within this range.
brown
blue
yellow/green
neutral
mass
fase