has several internal automatic functions which may not be noticed in the first instance but which, nonetheless,

may assist the operator in making best use of the projector.

lamp on timer 

This internal system in the electronic ballast governs the start up process so that if a prolonged unsuccessful attempt (over 20
seconds) is made to strike the lamp, the device will then automatically attempt to strike the lamp for 20 seconds once every
minute for the following 8 minutes. After this the lamp circuit is disabled (assumes a failed lamp).

This device protects the transformer and ignitor.

NOTE

: it is then necessary to remove the fixture from mains power and replace the lamp. 

temperature controlled cooling fans

A thermal sensor in the body of the 

Fiera

1200

constantly monitors the internal temperature of the fixture to ensure that it

remains at an optimal level. 
The electronic circuitry of the 

Fiera

1200

is designed to compensate for a rise in the internal temperature of the unit by

increasing the cooling fan speed.
In this manner, the internal components of the fixture are maintained in an optimal temperature range and the fans are opera-
ting at the minimal speed required, thus minimising any noise.

NOTE

:

If you wish to maintain the fans at the maximum operating speed, you may do this via the display function
(function 

FAN ON

) or directly by keeping DMX channel 8 at a level between 171 and 249.

automatic return to position

An encoder system based on 4 position indicators allows the

Fiera

1200

to return to its correct position if it is

accidentally moved during operation.

This is particularly useful if the projector is to be mounted on the floor in a position where the performer or artist
may accidentally bump the unit

NOTE

: this device may be deactivated (see section 11 Display panel functions - 

OPTO OFF

). to return to its correct position

if it is accidentally moved during operation.

Whilst every possible precaution has been taken to ensure the trouble-free operation of your 

Fiera

1200

the fol-

lowing periodic maintenance is highly recommended. Prior to undertaking any maintenance procedure, make
sure the fixture is disconnected from mains power.

Periodic cleaning
Lenses and reflectors

Even a fine layer of dust can reduce the luminous output substantially. Regularly clean all lenses and the reflector using a soft
cotton cloth, dampened with a specialist cleaning solution.

Fans and air passages

The fans and air passages must be cleaned approximately every 6 weeks; the period for this cleaning will depend, of course,
upon the conditions in which the projector is operating. Suitable instruments for performing this type of maintenance are a
brush and a common vacuum cleaner or an air compressor.

Periodic maintenance
Lamp

The lamp should be replace if there is any observable damage or deformation due to heat. This will avoid the danger of the
lamp exploding.

Mechanicals 

Periodically check all mechanical devices for wear and tear, gears, guides, belts, etc, replacing them if necessary. Periodically
check for mechanical damage and replace components as required. Check the tensioning of all belts and adjust if necessary.

Electrical components

Check all electrical components for correct earthing and proper attachment of all connectors, refastening if necessary.

Replacing fuses

Locate the fuses which protect the lamp and internal circuitry. These are indicated  by labels on the base of the 

Fiera

1200

.

Use a multimeter to check the condition of the fuse, replacing it with one of similar value if required.

Attention

Disconnect mains power prior to opening up any housing.

20. Maintenance

19. Automatic internal functions

44

English

Summary of Contents for Fiera 1200

Page 1: ...1st edition october 2003 instructions manual 1a edizione ottobre 2003 manuale di istruzioni 1200...

Page 2: ...assima rapidit e precisione Please note in the space provided above the relative service information of the model and the retailer from whom you purchased your Fiera 1200 This information will assist...

Page 3: ...e lamp in the optical path and adjusting the beam 37 14 Turning on the Fiera 1200 without articulated movement 37 15 Resetting the counter 38 16 Automatic repositioning functions 38 17 Altering the op...

Page 4: ...ls of the unit Isolate the projector from mains supply prior to performing any function which involves touching the internals of the unit including lamp replacement 2 For mains connection adhere stric...

Page 5: ...ed lamp life We recommend therefore that the lamp be replaced within the manufacturer s specified lamp life installing the lamp 1 Using a Philips head screwdriver loosen the 2 screws which affix the l...

Page 6: ...ed in the lamp s packaging The G 22 lampholder is sym metrical in construction DO NOT USE UNDUE FORCE In case of difficulty inspect for physical damage and then repeat the installation procedure 5 Sec...

Page 7: ...g the fixture from lighting truss coemar has included two cam lock devices A The two cam lock devices may be instal led in 2 diverse positions on the base of the Fiera 1200 These devices are 1 4 turn...

Page 8: ...ously affecting the proper ope ration of the fixture ambient temperature Never install the projector in locations where there is insufficient flow of circulating air the ambient temperature should not...

Page 9: ...ioni di sicurezza WARNING High voltage inside Disconnect from power supply before opening A good ground connection is essential Case is very hot Do not install on flammable surfaces min Distance from...

Page 10: ...ess each fixture Any number between 1 and 505 can be generated via the multifunction panel of the Fiera 1200 This procedure must be carried out on every unit When initially powered up each projector w...

Page 11: ...e unit if accidentally knocked out of place opto OFF LAMP lamp control Lamp on off via DMX signal or lamp always on FANS fans control Fans speed control through PCB depending on ambience temperature S...

Page 12: ...ure measurement 1 0 DMX value reading 255 DMX value reading enter o enter enter o o o o o TEMP temperature to measure the internal temperature in C DMIN DMX value on each channel reading of DMX value...

Page 13: ...and holding the button and then pressing and holding down the button will cause the display to jump to the lowest possible value associated with the respective parameter MEAS TEST o o lampeggia enter...

Page 14: ...ortional Tracking mode from fast to slow 128 247 50 97 proportional Tracking mode slow 248 255 97 100 6 no effect spare makes the light compatible with Electronic ballast version 7 no effect spare mak...

Page 15: ...til a flat even beam is produced with no noticeable hotspot This procedure may be useful in situations where the Fiera 1200 may need to be switched on in an enclosed space such as in its flight case 1...

Page 16: ...rating life of the projector have not been reset An encoder system based on 4 position indicators allows the Fiera 1200 to return to its correct position if it is accidental ly moved during operation...

Page 17: ...h the projector will be sup plied when in use 1 Remove the screws on the base housing using a Philips head screwdriver as shown in the diagram below completely remove the cover thus providing full acc...

Page 18: ...the unit 2 Select from either 208 230 or 240V by disconnec ting cable n 5 and moving it to the required volta ge To ensure a correct selection refer to the sticker located on the transformer Under no...

Page 19: ...veral optional filters which can be utilised to alter the dimensions of the output of the projectors to suit specific lighting applications All the lenses and diffusion filters are rotatable thus allo...

Page 20: ...g it 3 Remove the lense you intend to replace 4 Insert the new lense determining the rotated position you wish it to occupy Lenses are rotatable through 360 5 After installing the new lense reposition...

Page 21: ...you should find it necessary to loosen the individual barndoors to adjust their position ensure that you retighten them suf ficiently to avoid them sagging 18 2 2 Rotating the barndoors 1 The barndoo...

Page 22: ...y bump the unit NOTE this device may be deactivated see section 11 Display panel functions OPTO OFF to return to its correct position if it is accidentally moved during operation Whilst every possible...

Page 23: ...here is a problem with the TILT Encoders Check the sensors and all associated cabling on the wheel which is used to determine the TILT movement in the yoke SNER LINE SYNCHRONISATION Error Check and re...

Page 24: ...viso coemar reserves the right to effect modifications without notification manuale istruzioni instruction manual Fiera 1200 1 edizione ottobre 2003 1st edition october 2003 coemar spa viaInghilterra...

Reviews: