17.2 Selecting the transformer operating voltage.
This procedure allows you to alter the operating voltage for the electronic circuitry and motors in the fixture.
You will need to be aware of the mains voltage available to you in your particular installation.
1) Locate the transformer in the base of the unit.
2) Select from either 208, 230 or 240V by disconnec-
ting cable n° 5 and moving it to the required volta-
ge. To ensure a correct selection, refer to the
sticker located on the transformer.
Under no circumstances should cables number 7
and 8 be moved.
3) Replace the base cover and re-affix all screws as per their original positions.
4) Make a clear note of the new operating voltage and frequency on the outside of the base of the
Fiera
1200
.
factory set main at:
208V
230V
240V
50Hz
60Hz
40