READ CAREFULLY BEFORE MOUNTING AND USING THIS 
PRODUCT. FOR THE PUMP, REFER TO ITS MANUAL.

OPERATION

The OPTIMATIC 22 controller orders the automatic start and stop of the 
water  pump  when  opening  or  closing  any  tap  or  valve  of  the 
installation.When the water pump starts, it keeps running while it exists 
any tap opened in the system, giving a constant flow an pressure to the 
network.

CONSTRUCTION CHARACTERISTICS

- Inlet male 1'’
- Outlet  male 1''
- Special non return valve which avoids surges
- Security system avoiding the possibility for the machine to work without 

water

- Pressure gauge
- Tension LED (POWER) 

u

- Security system LED (ALARM)

v

- Pump-working LED (ON) 

w

- Manual start switch (RESET)

x

-  Integrated socket for motor connection according toDIN-IEC 884-1.
-  Cable with plug DIN 49 441 for connection to the electric supply.

TECHNICAL CHARACTERISTICS

- Tension:                                                ~220/240 V 
- Max. Intensity:                                       30(16)A
- Frequency:                                            50/60 Hz
- Protection:                                             IP44
- Max. temperature of water:                     60° C
- Max. Flow:                                             10.000 l/h
- Starting pressure:                                  1,5 bar-2,5 bar
- Max. pressure for use:

           10 bar

-  Max. Pump power:

          220/240V:3CV(2200W)

                                                                                                                   

HYDRAULIC CONNECTION (Fig.1)

Before proceeding with hydraulic connection it is essential to prime the 
pump  correctly.  The  electronic  controller  should  be  installed  always  in 
horizontal  position  with  the  overmolded  arrow  pointing  to  the  top, 
connecting the inlet opening (male 1”) directly to the pump and the outlet 
opening (male 1” ) to the network.

ATTENTION

The  water  column  between  the  pump  and  the  highest  point  of  the 
installation depends on the starting pressure. Here below, we give you a 
list with the height of the column and the maximum pressure which must 
supplies the pump.  

The adjustment of the starting pressure is made by the screw placed in the 
back side of the device (fig.4)

            ELECTRIC CONNECTION 
This  device  is  ready  to  be  connected  according  to  IEC 
364/NFC15100

.

Check  the  power  supply  to  be  ~220/240V.  Connect  the  pump  to 
OPTIMATIC 22 through the SCHUKO SOCKET. The OPTIMATIC 22 can 
be used with a single-phase pump with electrical input greater than 16 A.

WARNING

Bad connections may spoil the electronic circuit.
H07RN-F 3G1,5 type cables (Ø9÷12mm) must be used in order to ensure 
IP 44 protection. 

           STARTING

1.- Be sure that the pump is correctly primed, then slowly open a tap.

2.- Connect the electronic controller to the electric supply. The 

tension LED will lit (POWER).

3.-The pump starts working automatically and within a 

period of 20-

25 seconds the pressure gauge will reach approximately the maximum 
pressure provided by the pump. During its working the corresponding 
LED (ON) will be on.

4.-Close the tap indicated on point 1. After 10-12 seconds the  p u m p   w i l l  

stop. The tension LED (POWER) will be the only one to remain on.

Any problem after this procedure will be due to a defective pump priming.

AUTOMATIC RESET FUNCTION

This system makes a series of automatic starting after the device is in 
failure, searching to reset automatically the device without manual 
intervention. This system works as follows: 
The device is in failure due to lack of water, after 5 minutes in this state, 
the system will do a RESET of 25 seconds, to try to  priming the pump.  If 
the system achieves to prime the pump, the failure disappears and the 
pump is ready to work. If the failure persists, the system will try another 
RESET after 30 minutes. And it will be going on every 30 minutes for a 
period of 24h.  
If after all this attempts, the failure persists, the system will keep in failure 
until it won't be solved manually.

POSSIBLE PROBLEMS

1.- Pump does not stop:
a)    Water leak higher than 1,5 l/min. at some point:

Check the installation, taps, WC, etc.

b)  Manual start switch (RESET) is blocked:

Act on it several times,in case the problem persists consult your 
dealer.

c) Breakdown on the electronic card: proceed to its substitution.
d)  Incorrect electric connection: 

Verify the connections according to Fig.3.

2.- Pump does not start:
a)  Not enough water supply, the security system has been 

a c t i v a t e d  

and the LED (FAILURE) is on:
Check the water supply and restart the pump through the 

reset  switch 

(RESET).

b)     The pump is not hydraulically primed. The safety system against dry 

operation  has  been  activated  and  the  LED  (FAILURE)  is  on:  fill  with 
water the inlet, drain the water surplus in the installation opening a faucet 
located to he same level of the pump - to diminish the pressure of the 
water column over the flow sensor - and restore the operation  mode 
using the pushbutton RESET.

c)  Pump is blocked:

LED (FAILURE) is on, the security system is activated.
When we act on the manual start switch (RESET) the LED  ( O N )   i s  
activated but the pump does not work:
Consult your dealer.

d)  Failure in the electronic circuit:

Switch off power supply, wait a few seconds and turn it on again. If the 
pump does not start immediately  then replace the circuit.

e)  Not electrical supply:

C h e c k   t h e   p r o p e r   e l e c t r i c   f e e d i n g . T h e   t e n s i o n   L E D  
(POWER) should be on.

f)  Not enough pump pressure:

T h e   s e c u r i t y   s y s t e m   h a s   b e e n   a c t i v a t e d   a n d   t h e  
corresponding LED (FAILURE) is on. Check that the pump pressure is 
the one shown in the hydraulic connection table.

g)  Air  in the pump aspiration:

The pressure gauge will indicate a pressure lower than the nominal or 
constant oscillations. The security system will act by stopping the pump, 
the LED (FAILURE) will be on.
Check  the  sealing  of  the  connections  and  O-ring  of    the  aspiration 
conduct.

3.- The pump starts and stops repeatedly:
a)  Small leak in some point of the installation:

Verify possible tap or WC tank leaks and repair them.

DECLARATION OF CONFORMITY

We,  COELBO  CONTROL  SYSTEM  S.L.  declare  that  the  product   
OPTIMATIC 22, with type and serial number as shown on the name plate, 
are constructed in accordance with Directives   2006/95/EC, 2004/108/EC 
and  2002/95/EC  and  assume  full  responsability  for  conformity  with  the 
standards laid down therein .

 Terrassa, 04.2009 - Tehnical director - F. Roldán Cazorl

a

USING

HEIGHT

ADJUSTMENT

PRESSURE

MIN.PUMP

PRESSURE

10m                        1,5bar                         3bar
15m                        2,0bar                         3,5bar
20m                        2,5bar                         4bar