13
E. Programming Options
Default settings in BOLD
OPTION
DESCRIPTION
Option Bank 0 - 3 Chirps (Learn Transmitters)
Option Bank One - 4 Chirps (Keyless & Alarm Options)
STATUS INDICATOR
1. Lock with Ignition
Doors lock when all doors are closed and
ON
OFF
ignition is turned on
2. Delayed Door Lock
3 sec. delay locking for theater dimming
ON
OFF
3. Extended Locks
Lock duration is (1) 5 sec. or (2) 0.6 sec.
ON(1) OFF(2)
4. Unlock with Ignition
Doors unlock when ignition is turned off
ON
OFF
5. Double Unlock Pulse
Unit provides two pulses on each unlock
ON
OFF
6. Confirmation Chirps
(1)Yes (2) No confirmation chirps
ON(1) OFF(2)
7. Real Panic Horn Output (1) Random pulsed (2) Steady pulsed output
ON(1) OFF(2)
8. Passive Arming
Alarm automatically arms 60 sec.
ON
OFF
after ignition is turned off
Option Bank Two - 5 Chirps (Installer Options)
1. Door Trigger Polarity
(1) Positive (2) Negative
ON(1) OFF(2)
2. Lite Touch adj
ARM raises sensitivity; DISARM lowers sensitivity
ON
OFF
3.Full Shock adj
ARM raises sensitivity; DISARM lowers sensitivity
ON
OFF
2. System Power-Up and Programming,
cont’d
D. Adjusting the Onboard IT-s
TM
(Interior Theft Sensor)
The IT-s
TM
is factory pre-set at a moderate sensitivity level and has
two adjustment points: Lite-Touch and Full Shock.
To adjust Lite-Touch sensitivity:
1. Enter programming Option Bank 2/Feature 2.
2. Press ARM to increase sensitivity. Press DISARM to decrease
sensitivity.
3. Strike vehicle to test. Chirp will verify impact.
4. Pressing ARM until no siren/horn chirps are heard will disable
Lite-Touch IT-s
TM
.
To adjust Full-Shock sensitivity:
1. Enter programming Option Bank 2/Feature 3.
2. Press ARM to increase sensitivity. Press DISARM to decrease
sensitivity.
3. Strike vehicle to test. Chirp will verify impact.
4. Pressing ARM until no siren/horn chirps are heard will disable
Full-Shock IT-s
TM
.