Unpacking the equipment

On receiving your BUC system, check the contents against the packing list. Make sure 
that all equipment itemised on the packing list is present and that there is no damage to 
the equipment before you start installing the equipment.

If anything is missing or damaged, please contact your nearest Codan office immediately 
to obtain the correct warranty service procedures. This ensures prompt assistance, 
minimal turnaround time, and avoids any freight issues.

We recommend that the equipment is installed by qualified and experienced personnel, 
to the relevant standards and approvals.

Installing the BUC equipment

For information on electromagnetic compatibility requirements and safety notices, 
please see the reference manual for the product.

WARNING

All equipment that is mounted outdoors 

must

 be adequately 

weatherproofed.

Use self-amalgamating tape to seal connectors and cable entry points, 
from the connector to the cable sheath (see 

Application Note: Sealing 

N-type and MS connectors in satellite equipment installations

, 17-60094).

Ensure all W/G joints are properly sealed with the appropriate gasket (see 

Application Note: Waveguide gasket kits

, 17-60128).

CAUTION

Water is the most common cause of poor performance in VSAT 
installations. Ensure that all cables and W/G junctions are properly sealed.

WARNING

A radiation hazard exists if the BUC is operated with its RF output 
unterminated.

WARNING

The BUC must be installed in a restricted access location with appropriate 
warning signs displayed.

CAUTION

Codan disclaims any liability or responsibility for the results of improper 
or unsafe installation practices.

Summary of Contents for 4908-MINIBUC

Page 1: ...au INSTALLATION Ku Band BUC systems Overview Codan provides a range of BUCs of varying power ranges that operate in basic single BUC systems or redundancy systems These BUCs operate in the C Band and...

Page 2: ...equirements and safety notices please see the reference manual for the product WARNING All equipment that is mounted outdoors must be adequately weatherproofed Use self amalgamating tape to seal conne...

Page 3: ...l power to the site Install any other mounting structures Connect the equipment together using appropriate cables Set up the indoor and outdoor equipment to station parameters See page 12 Essential ri...

Page 4: ...universal boom mounting kit suitable for the Codan range of L M RBUCs Contact your antenna manufacturer if you have specific installation requirements It is recommended that BUCs are installed as clo...

Page 5: ...ounted on the pole at the base of the antenna with the mounting hardware supplied DC may be supplied to the BUC via the BIAS T connector on the 6580B using the Tx IF coaxial cable or via the AUX termi...

Page 6: ...power cable or re terminate the cable supplied Table 1 lists the pin connections and describes the input functions available on the DC INPUT connector on the BUC WARNING Before applying power to the B...

Page 7: ...ins cable or re terminate the cable supplied Table 2 lists the pin connections and describes the input functions available on the AC INPUT connector on the BUC WARNING Voltages outside of these limits...

Page 8: ...C pipe for example or supported by an overhead catenary wire If the transmit and receive IF coaxial cables are identical mark the cables at each end before you install them Also ensure that there is e...

Page 9: ...apillary action Water and sometimes dust within a connection or cable attenuates the signal In extreme cases water causes a short circuit and corrosion within the connection or cable If water has ente...

Page 10: ...antenna AC mains Tx to antenna L Band Tx IF 24 48 V DC power DC powered BUC only 10 MHz Ref FSK M C L Band Rx IF 15 V DC power nominal 10 MHz Ref RS232 422 485 M C L Band Modem TRF BUC LNB External A...

Page 11: ...nsions for your BUC M C Rx from antenna AC mains Tx to antenna L Band Tx IF 10 MHz Ref FSK M C L Band Rx IF 15 V DC power nominal 10 MHz Ref RS232 422 485 M C L Band Modem TRF BUC LNB Data External in...

Page 12: ...on In the case of lightning strikes large ground currents occur for several hundred metres around a strike area causing large voltage potentials between separate earth points For this reason some ligh...

Page 13: ...y 36 32 00800 080 Washer M8 Stainless steel Flat qty 36 32 00801 080 Washer M8 Stainless steel Spring qty 36 32 00801 280 Bolt M8 50 Stainless steel Hex qty 4 32 00850 080 Table 4 Kit Mounting 8 to 12...

Page 14: ...sher M8 Stainless steel Spring qty 14 32 00801 280 Screw M8 50 Stainless steel Hex qty 4 32 00850 080 Table 6 Kit Mounting 12 Pole PSU 15 40147 Description Component part number Rod Threaded M8 375 mm...

Page 15: ...steel Socket cap qty 5 31 24016 980 Gasket W G Circular cross section 3 32 WR75 78 23024 Table 8 Kit Flange WR75 Universal 15 40174 Description Component part number Nut M4 Stainless steel Hex qty 5...

Page 16: ...Sealing kits Table 9 Kit Connector Sealing 15 40202 Description Component part number Application Note Sealing N type and MS connectors in satellite equipment installations 17 60094 Tape Vinyl Elec 19...

Page 17: ...ng Universal to 100 W BUC 15 42072 001 sheet 1 Boom Mounting Universal 7580 PSU 15 42072 001 sheet 2 Pole Mounting 8 to 12 RBUC C Ku 15 42098 001 PSU 5586 8 pole 15 40128 001 PSU SSPA 12 pole 15 40147...

Page 18: ...Ku Band BUC systems Page 18 of 18 12 50176 EN Issue 2 December 2010 This page has been left blank intentionally...

Page 19: ...15 42072 001 sheet 1...

Page 20: ...15 42072 001 sheet 2...

Page 21: ...15 42098 001...

Page 22: ...15 40128 001...

Page 23: ...15 40147 001...

Page 24: ...01 01192 CODAN...

Page 25: ...01 01828...

Page 26: ...01 01302...

Page 27: ...01 01689...

Page 28: ...01 01785...

Reviews: