Coda TEPEX 2S Instruction Manual Download Page 8

 

 
 
 
 
 
 
 

Instruction manual of distancemeter TEPEX 2S - May 2021 version                                                 

Page 6 / 12 

 

 

ACTION = display 

Allows  the  reading  of  the  previous  measurement  which  figures  by  pressing 
successively  (Back  out  of  the  display  by  a  short  press  on 

FUNCTION

)  and  the 

subtracting the distance between the apparatus and the rock massif  after pressing 

MEMO

 in search of minimum distance. 

The 

display 

mode

  allows  to  wipe  out  all  of  the  memorized  data  by  an  extended 

press on

 

MEMO

 as long as the screen flashes

 

MEMO. = mémory

 

 

MEASUREMENT 

 

DISPLAY 

 

 

 

 

  

 

 

 

 

 

 

 
 
 

100 number memory..  

 

The  101

ème

  measurement  replaces  01  if 

not wiped out 
 

Subtract 5m minimum measured

 

(

distance between the apparatus 

 and the rock massif

  

).

 

 

The  screen  flashes,  then  all  of  the 
memory is wiped out. 

 
Return to number 1.

 

MEMORY 

 
 
 
 

Measurement reading  

 

Return :  search  for 
minimum distance

 

 

Starting up 

Localization of the probe 

Search for 

minimum distance 

Loupe mode 

  

                  

 
 
 

                                        

 

 

 

Registration 

of minimum distance 
Wipe out, begin again

 

Measurement memory 

 

 

 

Running measurements 

 

    

    

             

1                  

              

Memory wipe 

Summary of Contents for TEPEX 2S

Page 1: ...S 3 32 27 7 v vo oi ie e r ro om ma ai in ne e 2 24 41 10 00 0 L LE EM MB BR RA AS S F Fr ra an nc ce e 3 33 3 0 0 5 5 5 53 3 2 22 2 8 82 2 3 36 6 w ww ww w c co od da a t te ep pe ex x e eu u I IN N...

Page 2: ...NTATION OF THE EQUIPMENT 1 1 II TECHNICAL SPECIFICATIONS 2 2 III THE EMITTER PROBE 3 3 IV THE READING BOX 4 4 V THE LASER TELEMETER 4 4 VI TAKING A MEASURE 5 5 VII INSTRUCTIONS A CONTROL KEYS 5 5 B WO...

Page 3: ...easures The TEPEX 2S is appropriate for quarries and civil engineering The measurement range stretches from 2 5 m to 15 m This measurement is expressed in meters m and by centimeters cm up to 6 m by 2...

Page 4: ...ial being gone through or the type of environment The disruption remains negligible as long as the rock contains little or no metallic mineral elements and the level of interference remains that of a...

Page 5: ...obe is in horizontal position or when the voltage is insufficient The information low battery is transmitted to the reading box The rope provided is graduated every meter from the bottom of the probe...

Page 6: ...or and the coalface A visible laser beam identifies the target point The scope is 30 m with an accuracy of 2 mm For all information see the instructions in the description of the laser telemeter Don t...

Page 7: ...n of the reading box by a long press In working mode a short press allows to enter the minimum distance An another short press clears the distance for a new measurement The measurement mode allows o t...

Page 8: ...ll of the memorized data by an extended press on MEMO as long as the screen flashes MEMO m mory MEASUREMENT DISPLAY 100 number memory The 101 me measurement replaces 01 if not wiped out Subtract 5m mi...

Page 9: ...o far away or absent The bar graph indicates the approach of the probe Memory line 4 4 m distance of the probe varies depending on the position of the operator Burden measurement 4 3 m minimum fixed d...

Page 10: ...TEPEX 2S May 2021 version Page 8 12 2 Working display READING Enter in memory display Out by pressing on FUNCTION Running of memorized measurements WIPE OUT Complet memory wipe out Flashing screen Mem...

Page 11: ...lows finely locate the probe in difficult cases The sensitivity of the reading box is increased at the signal of the probe This function allows only the location of the probe The value is not stored L...

Page 12: ...installer is available for download on the site https www coda tepex eu in the heading DISTANCEMETER This software allows to edit a plug control drilling Documentation on the site The connection read...

Page 13: ...Instruction manual of distancemeter TEPEX 2S May 2021 version Page 11 12 Plug control drilling...

Page 14: ...nd the reading box must be 8 00 metres The probe must be vertical as well as the reading box They must be positioned at the same height Put new batteries in the reading box and in the probe The test m...

Reviews: