Coda TEPEX 2S Instruction Manual Download Page 11

 

 
 
 
 
 
 
 

Instruction manual of distancemeter TEPEX 2S - May 2021 version                                                 

Page 9 / 12 

 

3 - Loupe - Precise localization 
 

 

The Loupe mode allows finely locate the probe in difficult cases. The sensitivity of the reading 
box is increased at the signal of the probe. 
 

This function allows only the location of the probe. The value is not stored. 

 

LOCALIZATION 

                

 

 
 

 
 
 
 
 
 

 
 
 
 

 

Input  Loupe  by  pressing

 

MEMO

 

Direction of variation 
 

=   : 

rapprochement   

 

  : remoteness

 

 

 

Output Loupe by pressing

 

MEMO

.

 

Summary of Contents for TEPEX 2S

Page 1: ...S 3 32 27 7 v vo oi ie e r ro om ma ai in ne e 2 24 41 10 00 0 L LE EM MB BR RA AS S F Fr ra an nc ce e 3 33 3 0 0 5 5 5 53 3 2 22 2 8 82 2 3 36 6 w ww ww w c co od da a t te ep pe ex x e eu u I IN N...

Page 2: ...NTATION OF THE EQUIPMENT 1 1 II TECHNICAL SPECIFICATIONS 2 2 III THE EMITTER PROBE 3 3 IV THE READING BOX 4 4 V THE LASER TELEMETER 4 4 VI TAKING A MEASURE 5 5 VII INSTRUCTIONS A CONTROL KEYS 5 5 B WO...

Page 3: ...easures The TEPEX 2S is appropriate for quarries and civil engineering The measurement range stretches from 2 5 m to 15 m This measurement is expressed in meters m and by centimeters cm up to 6 m by 2...

Page 4: ...ial being gone through or the type of environment The disruption remains negligible as long as the rock contains little or no metallic mineral elements and the level of interference remains that of a...

Page 5: ...obe is in horizontal position or when the voltage is insufficient The information low battery is transmitted to the reading box The rope provided is graduated every meter from the bottom of the probe...

Page 6: ...or and the coalface A visible laser beam identifies the target point The scope is 30 m with an accuracy of 2 mm For all information see the instructions in the description of the laser telemeter Don t...

Page 7: ...n of the reading box by a long press In working mode a short press allows to enter the minimum distance An another short press clears the distance for a new measurement The measurement mode allows o t...

Page 8: ...ll of the memorized data by an extended press on MEMO as long as the screen flashes MEMO m mory MEASUREMENT DISPLAY 100 number memory The 101 me measurement replaces 01 if not wiped out Subtract 5m mi...

Page 9: ...o far away or absent The bar graph indicates the approach of the probe Memory line 4 4 m distance of the probe varies depending on the position of the operator Burden measurement 4 3 m minimum fixed d...

Page 10: ...TEPEX 2S May 2021 version Page 8 12 2 Working display READING Enter in memory display Out by pressing on FUNCTION Running of memorized measurements WIPE OUT Complet memory wipe out Flashing screen Mem...

Page 11: ...lows finely locate the probe in difficult cases The sensitivity of the reading box is increased at the signal of the probe This function allows only the location of the probe The value is not stored L...

Page 12: ...installer is available for download on the site https www coda tepex eu in the heading DISTANCEMETER This software allows to edit a plug control drilling Documentation on the site The connection read...

Page 13: ...Instruction manual of distancemeter TEPEX 2S May 2021 version Page 11 12 Plug control drilling...

Page 14: ...nd the reading box must be 8 00 metres The probe must be vertical as well as the reading box They must be positioned at the same height Put new batteries in the reading box and in the probe The test m...

Reviews: