7. WARRANTY

7 .1 Warranty 

CODA Audio guarantees the LINUS14/14D amplifier to be free from defective material and/or workmanship for a period 
of five (5) years from the date of sale. When a defect occurs under normal installation and use, CODA Audio will repair the 
product under this warranty. In this event, please return the amplifier to your dealer/distributor together with a copy of 
your sales receipt as proof of purchase. 
This warranty provides that examination of the returned product must indicate in our judgement a manufacturing defect. 

7.2 Items excluded from this warranty 

CODA Audio is not liable for any damage caused by shipping accidents, misuse, abuse, operation with incorrect AC 
voltage, operation with faulty peripheral equipment, modification or alteration without prior factory approval, service by 
an unauthorized service centre and normal wear and tear. Amplifiers on which the serial number has been removed or 
defaced are not eligible for warranty service. 

7.3 What CODA Audio will do 

CODA Audio (or its appointed agent) undertakes to rectify any defect regardless of the reason for failure (unless excluded 
from this warranty), by repair, replacement or refund as it sees fit. 

7.4 How to obtain warranty service  

You must notify your dealer/distributor of your need for warranty service. All components must be shipped in the original 
packaging.

7.5 CODA Audio’s product improvement 

CODA Audio reserves the right to improve the technical standard of its products without giving prior notice. If in any 
doubt, please consult your dealer/distributor or contact CODA Audio directly for clarification. We are always working 
on making CODA products even better and accessible all over the world. Please check our website for the latest list of 
approvals and certificates.

7. WARRANTY

Summary of Contents for LINUS14

Page 1: ...4D The leading version of this brochure is the English one which shall prevail to the exclusion of the national translation on hand USER MANUAL v1 0 Copyright 2010 2020 by CODA Audio GmbH LIMIT SIGNAL...

Page 2: ...ny Telephone 49 0 511 866 55 888 Fax 49 0 511 866 55 887 Internet www codaaudio com Email contact codaaudio com Subject to change Please visit our website www codaaudio com for the latest version of t...

Page 3: ...al inputs 22 3 5 Remote control inputs Ethernet 23 3 6 Power outputs 23 4 OPERATION 24 4 1 Screen user interface 24 4 2 Power amp protection systems 27 4 3 Mains protection 28 4 4 Main SMPS protection...

Page 4: ...present on the metal casing and surrounding conductors The main power switch on the front panel is a soft switch Ensure that the mains power can be isolated from the amplifier at any time 6 Power cord...

Page 5: ...exhibits a distinct change from its normal function or performance in case the amplifier has been used in a dusty environment for quite a period of time 14 Servicing All service and repair work must b...

Page 6: ...SURE THE EXCLAMATION MARK IS INTENDED TO ALERT THE USER TO IMPORTANT INSTRUCTIONS ALSO FOR MAINTENANCE IN THE LITERATURE ACCOMPANYING THE AMPLIFIER CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN THE AMPLI...

Page 7: ...2 2010 Immunity for all environments E1 residential to ES industrial The operating conditions and application environments presupposed in the information for use user manual are to be kept accordingl...

Page 8: ...pr sentes sur le chassis m tallique L interrupteur lectrique tant un mod le soft assurez vous de la bonne isolation de l amplificateur par rapport l alimentation lectrique 6 Protection du cordon d al...

Page 9: ...le mode d emploi l amplificateur a t utilis dans un environnement poussi reux pendant un temps prolong 14 Entretien Toute op ration de maintenance ou r paration doit tre effectu e par un revendeur dis...

Page 10: ...EXCLAMATION SERT GALEMENT A AVERTIR L UTILISATEUR D INSTRUCTIONS IMPORTANTES POUR L ENTRETIEN CONTENUES DANS LA DOCUMENTATION DE L AMPLIFICATEUR ATTENTION RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR L AMPL...

Page 11: ...Immunit pour tous les environnements E1 r sidentiel a E5 industriel Les conditions d utilisation ainsi que les environnements d exploitation d crits dans le mode d emploi sont respecter scrupuleuseme...

Page 12: ...einem dedizierten Erdungsleiter angeschlossen werden Bei dem Verst rker handelt es sich um ein Ger t der Ger teklasse 1 welches zu jeder Zeit geerdet sein muss Fehlende Erdung kann unerwartete und ho...

Page 13: ...ch ttet Fremdk rper sind in den Verst rker gelangt der Verst rker war Regen oder Feuchtigkeit ausgesetzt der Verst rker wurde mechanisch besch digt das Netzkabel der Netzstecker sind besch digt der Ve...

Page 14: ...TZER AUF WICHTIGE BEDIENUNGS UND WARTUNGSANLEITUNGEN IN DER DEM VERST RKER BEIGEF GTEN LITERATUR AUFMERKSAM MACHEN VORSICHT NICHT FFNEN STROMSCHLAGGEFAHR DER VERST RKER DARF NUR IN H HE BIS 2000 M EIN...

Page 15: ...2 2010 St rfestigkeit f r alle Umgebungen E1 Wohngebiete bis ES gewerblich Die in den Benutzerinformationen angegebenen Betriebsbedingungen sind entsprechend einzuhalten Svetlomir Aleksandrov EU Konf...

Page 16: ...driver and cabinet components Further benefits to this approach include substantial reductions in cost and quicker times to market for new products We have a wide product range offering high quality...

Page 17: ...on which significantly reduces the weight and size only 2U of the amplifier Using SMPS the seamlessly regulated symmetrical supply voltages of the power amplifier are more stable and efficient than th...

Page 18: ...PEAKON connector 15 LiNET network connections 19 Cooling air outlet vents 1 IN 1 OUT AES EBU 20 XLR Line inputs 16 AUX connection alarm override 21 Ethernet connector for remote access LIMIT SIGNAL SE...

Page 19: ...four screws and washers when mounting the amplifier to the front rack rails For mobile use the amplifier should also be secured using the 19 mounting elements on the rear panel LINUS14 14D 3 INSTALLA...

Page 20: ...ry large breaker Always respect this rule of thumb for good installation practice for guaranteeing long term reliable robust and safe operation one LINUS14 14D one circuit breaker As soon as the ampli...

Page 21: ...Equipment with rated current 75 A and subject to conditional connection IEC 77A 929 CDV 2016 If in any doubt consult your local power provider Never attempt to measure this impedance level with your m...

Page 22: ...digital audio streams to other AES EBU compatible devices like other LINUS14 14D amplifiers for example Please note that although the AES EBU and Ethernet connectors use the same connector type RJ45 t...

Page 23: ...lifier output Pin 2 Channel 4 inverted SPEAKON Output 3 Pin 1 Channel 1 amplifier output Pin 1 Channel 1 inverted Pin 2 Channel 2 amplifier output Pin 2 Channel 2 inverted Pin 3 Channel 3 amplifier ou...

Page 24: ...LED off Sensor loop is closed 4 1 1 Module number Move the selection field with the encoder knob to the module number and push to enter selection Turn encoder knob to select a number from 1 to 250 and...

Page 25: ...ing page Array type in total amount of used line array elements in one hang Sizing High Shelf Human EQ Low Boost Sub Sonic Go to position EQ and push the encoder knob to enter FULL PARAMETRIC EQ s pag...

Page 26: ...ash fast LiNET source can be recovered by pressing CH buttons 1 2 4 1 9 Lock device Navigate to the device overview page and select the LOCK function Define your new password in numbers and confirm Af...

Page 27: ...for persistent DC voltage levels If the 10 V threshold voltage is exceeded at any of the outputs the SMPS will be automatically switched off to prevent further damage from overload to the power ampli...

Page 28: ...rotection In case of extremely high output levels with heavily clipped output signals and low loudspeaker impedances 2 5 this additional protection will reduce the amplifier stage output power very qu...

Page 29: ...hted Frequency response 8 load with CLEAR preset 20 Hz 20 kHz 0 0 dB 1 0 dB THD N IMD 4 load 1 2 output power 20 Hz 20 kHz 0 005 Latency input to loudspeaker output Minimum 2 70 ms AES EBU input Minim...

Page 30: ...quency 47 63 Hz Power consumption 1 4 power 600 W 4 to represent typical music signal Amplifier in standby 17 6 W Amplifier idle 191 W Amplifier power 3200 W AC Mains Input Input sources Analog AES EB...

Page 31: ...ut current 52 A pk Damping factor 8 load 1 kHz and below 2500 Minimum output load 2 nom 2 7 for sensor control Power output connections 2 x Neutrik NL4 speakON 1 x Neutrik NL8 speakON LINUS14 14D 5 SP...

Page 32: ...2 x 22 05 Volume 0 049 m 1 73 ft Net weight 14 75 kg 32 5 lbs Shipping weight 17 5 kg 38 6 lbs LINUS14 14D 5 SPECIFICATION Physical Typical values some variation may exist due to component tolerances...

Page 33: ...igure 6 3 THD N w AES17 filter 50 dBu 10 dBu 4 measurement of a typical performance 6 PERFORMANCE NEED PIC Size Correct NEED PIC Size Correct NEED PIC Size Correct 20 00 Hz 100 00 1000 00 10000 00 1 5...

Page 34: ...of a typical performance Figure 6 5 Common mode rejection 20 Hz 20 kHz measurement of a typical performance LINUS14 14D 6 PERFORMANCE 20 00 Hz 100 00 1000 00 10000 00 200 00 150 00 100 00 50 00 0 00 d...

Page 35: ...actory approval service by an unauthorized service centre and normal wear and tear Amplifiers on which the serial number has been removed or defaced are not eligible for warranty service 7 3 What CODA...

Page 36: ...ISA MasterCard Shipping address To transport the amplifier the original packing materials must be used Please return the amplifier to the following address or your nearest CODA Audio appointed distrib...

Page 37: ...for Audio Video or similar Electronic Appliances In order to guarantee the safe functioning of the amplifier it has to be checked regularly depending on its application but at least once a year by a p...

Page 38: ...14 14D 11 NOTES NOTE IMPORTANT Please consider that any changes made to the amplifier have to be documented in writing and passed on to the buyer in the event of resale 11 NOTES CHANGES MADE TO THE AM...

Reviews: