background image

 
 
 
II RECEIVER

 

 

NOTE: 

 Insure that the proper channel has been selected before preceding with the 
alignment procedure. 

 
1. Power Supply Voltage 

 The proper voltage for testing is 6.0 VDC. 

2. Receiver Alignment

 

 A. Connect an RF signal generator or Communications Service Monitor to the 
   antenna connector. 
 B. Connect a SINAD meter and oscilloscope across the speaker terminals. 
 C. Set the output level of the RF signal generator for -47 dBm. The generator should be set 

for +/- 1.5 KHz deviation of a 1 KHz tone. 

 D. Set the audio output level for 0.6 Vrms. by adjusting volume. 
 E. Reduce the output level of the RF signal generator for produce a 6-12 dB 
    SINAD indication. 

III. WEATHER

  

1. Power Supply Voltage 

The proper voltage for testing is 6.0 VDC 

2 weather 

Alignment: 

    

A. Connect an RF signal generator or Communications Service Monitor to the 

   antenna connector. 
    B.Connect a SINAD meter and oscilloscope across the speaker terminals.     

   

C.Set the output level of the RF signal generator for -47 dBm. The generator should be 

set for +/- 3 KHz deviation of a 1 KHz tone. 

   

D.Set the audio output level for 0.6 Vrms. by adjusting volume. 

   E: educe RF output level to equal or less than 

118dBm  with condition of SIND=12Db.  

Reviews: