Fig. 9
Fig. 10
When should I change the oil?
The first oil change should be carried out after 50
operating hours, and then every 250 operating hours.
Changing the oil:
1. The log ram must be in its starting position.
2. Place a container under the log splitter to catch the old oil.
The container should have a capacity of at least 4 litres.
3. Unscrew the dipstick. Do not drop or lose the oil seal when
removing the dipstick.
4. Now tip the machine to empty the oil into the container.
5. Stand the log splitter on end, with the filler opening at the
top. Fig 9.
A second person will be required to up-end and
hold the log splitter.
6. Pour in the new hydraulic oil (3.2 litres) using a clean
funnel.
7. Clean the dipstick and the oil seal.
8. Check the oil seal and replace it if it is damaged in any
way.
9. Replace the dipstick and screw it firmly into place.
Caution! Do not tighten the screw too tightly, since this may
damage the oil seal or the thread in the cylinder cover.
Dispose of the old oil properly (local oil disposal
point). The old oil must not be poured into the
ground or drainage system, or mixed with other
waste.
L
Hydraulic oil
We recommend the following hydraulic oils for the hydraulic
cylinder:
¾
Shell Tellus T 22
¾
Aral Vitam Gf 22
¾
BP Energol HLP 22
¾
Mobil DTE 11
¾
or equivalent
Do not use any other types of oil. The use of any other
type of oil will adversely affect the operation of the
hydraulic cylinder.
G
G
u
u
a
a
r
r
a
a
n
n
t
t
e
e
e
e
This product is warranted in accordance with legal regulations for a
24 month period effective from the date of purchase by the first
user.
This product will not be covered if used in a commercial
application.
This warranty covers all material or production failures,
it does not include: defects from normal wear and tear, parts such
as, bearings, brushes, cables, brake pad, clutch disc, tyre, wheel,
belts, cutter blades, lubricant oils and grease or accessories.
Damage or defects resulting from abuse, accidents or alterations,
natural fading of painted or plated surfaces, sheet peeling and
other natural deterioration.
Any damage that occurs from the use of non-genuine Cobra parts
will not be covered.
We reserve the right to reject any claim where
the purchase cannot be verified or when it is clear that the product
was not maintained properly. (Clean ventilation slots, carbon
brushes and serviced regularly)
Expenses incidental to the
warranty claim that are not covered
.
Any damage resulting from
operating methods other than those indicated in the owner’s
manual will not be covered.
Dipstick