14 |
P a g e
CAUTION:
Do not connect the inverter and another AC source (such as a generator or utility power) to
the AC wiring at the same time. The inverter will be damaged if its output is connected to AC voltage
from another source. Damage can even occur if the inverter is switched off.
CAUTION:
Do not connect the inverter to an AC branch circuit that has high-power consumption loads.
It will not operate electric heaters, air conditioners, stoves, and other electrical appliances that
consume more than 500 watts.
CAUTION:
Loose connectors result in excessive voltage drop and may cause over heated wires and
melted insulation.
CAUTION:
Reverse polarity connections (positive to negative) will blow internal fuses in the inverter and
may permanently damage the unit. Such damage is not covered by the warranty.
CAUTION:
We recommend a main fuse in the battery’s positive cable to protect against DC wiring short
circuits (external to the inverter). The fuse should be as close to the battery as possible.
We recommend a
60 Amp ANL fuse or equivalent
. The specific fuse ampere rating should be sized to allow operation
of all your DC powered equipment.
CAUTION:
Remove any jewelry (watch, ring, etc.). Be careful not to short circuit the battery with any
metallic object (wrench, etc.).
CAUTION:
Electrical installations must meet local and national wiring codes, and should be performed
by a qualified electrician.
WARNING:
If you are making a permanent AC connection to the inverter, make sure that the AC wiring
steps are performed before any DC wiring is done. (DC hook-up energizes internal components,
regardless of the position of the On/Off Switch). Working on AC connections in such a circumstance
may result in an electric shock.
WARNING:
115 volt AC power is potentially lethal. Do not work on AC wiring when it is connected to the
inverter (even if it is switched off) unless the DC power source is physically disconnected from the
inverter. Also, do not work on AC wiring if it is connected to another AC power source such as a
generator or the utility line.
WARNING:
You may observe a spark when making the connection because current can flow to charge
the capacitors in the inverter. Do not make this connection in the presence of flammable fumes.
Explosion or fire may result. Thoroughly ventilate the battery compartment before making this
connection.