background image

Intro

Operation

Customer

Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

3

Nothing Comes Close to a Cobra

2

Important Safety Information

Intro

Operation

Customer

Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Introduction

WARNING Power inverters contain components  

that tend to produce arcs or sparks. To prevent  

fire or explosion, do not install the inverter in  

areas or compartments containing batteries or 

flammable materials or in locations that require 

ignition-protected equipment.
WARNING To reduce the risk of fire, do not cover  

or obstruct the ventilation openings. Do not install 

inverter in zero-clearance compartment.

Proposition 65: Warning: Wash Hands After 

Handling Power Cord

The power cord on this product contains lead, a chemical 

known in the state of California to cause birth defects or 

other reproductive harm.

Caution: Rechargeable Appliances

Certain chargers for small nickel cadmium batteries  

can be damaged if connected to the Cobra 2500 watt 

inverter. Two particular types of equipment are  

prone to this problem: 

1.  Small battery-operated appliances 

such as flashlights, razors, and 

night lights that can be plugged 

directly into an AC receptacle to 

recharge.

2.  Certain battery chargers for 

battery packs used in hand  

power tools. These chargers have 

WARNING label stating that 

dangerous voltages are present  

at the battery terminals.

This problem does not occur with the vast majority of 

battery operated equipment. Most use a separate charger 

or transformer that is plugged into the AC receptacle 

and produces a low voltage output. If the label on the AC 

adapter or charger states that it produces a low voltage  

AC or DC output (less than 30 volts), the inverter will  

have no problem powering the adapter safely.

Cobra 2500 Watt Output Waveform

Some very sensitive electronic equipment may not operate 

satisfactory on “square wave” or “modified sine wave.” 
The output waveform is referred to as “square wave” or 

“modified sine wave.” It is a stepped waveform designed 

to have characteristics similar to the sine wave shape of 

utility power.
A waveform of this nature is suitable for most AC loads 

(including linear and switching power suppliers used in 

electronic equipment, transformers and motors).

Important Safety Information

Intro

Operation

Customer

Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Introduction

Plug In Directly

Dangerous 

Voltages

CPI2590_MANL.indd   2-3

12/5/14   2:11 PM

Summary of Contents for CPI2590

Page 1: ...owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance services For Assistance in the U S A Automated Help Desk English o...

Page 2: ...Notes Notice Main Icons Secondary Icons Caution Warning Installation Contents Introduction Our Thanks to You A1 Customer Assistance A1 Product Features A2 Important Safety Information 1 Quick Evaluat...

Page 3: ...g and using it Special attention must be paid to the CAUTION and WARNING statements in the manual CAUTION Statements specify conditions which could cause damage to the unit or other equipment WARNING...

Page 4: ...nd night lights that can be plugged directly into an AC receptacle to recharge 2 Certain battery chargers for battery packs used in hand power tools These chargers have a WARNING label stating that da...

Page 5: ...es for a full 2500 Watt load 3 A test load that can be plugged into the AC receptacle on the inverter for short term testing at a low power level The following cables are recommended for testing low p...

Page 6: ...ce compartment Overheating may result CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will not work with a 6 volt battery and will be damaged if i...

Page 7: ...n on the inverter to the off position If the power source is a DC power supply switch it off as well 2 Connect cables to the Power Input Terminals on input end of the inverter The red terminal is posi...

Page 8: ...m the Positive Red Terminal of the inverter to the Positive Terminal of the power source the battery s main fuse or the battery selector switch if you are using one Make a secure connection NOTE Pleas...

Page 9: ...dary Icons Caution Warning Installation Installation Intro Operation Customer Assistance Warranty Notes Notice Main Icons Secondary Icons Caution Warning Installation Installation Laptop 100 watts x 2...

Page 10: ...the unit s power status and alarms for conditions that could cause it to shut down Power on The Voltage Input and Power Output indicators automatically toggle between input and output values at three...

Page 11: ...wn to indicate Over Voltage Protection and an alarm will sound To restore normal operation return the DC input voltage to less than 15V The inverter will automatically return to normal operation High...

Page 12: ...the input voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 5V 0 5V This protects the inverter against excessive input voltage Although the inverter has protect...

Page 13: ...ivery to the Cobra Factory Service department accompanied by proof of the date of first consumer purchase such as a duplicated copy of a sales receipt You must pay any initial shipping charges require...

Page 14: ...ransit to Cobra Factory Service Cobra Electronics Corporation 6500 West Cortland Street Chicago Illinois 60707 USA 6 If the power inverter is in warranty upon receipt of your power inverter it will ei...

Page 15: ...24 Notes...