Low Voltage Protection – If the 

DC input voltage drops below  

the alarm threshold of 11.3V +/- 

0.3V the meter will flash as shown 

to indicate Low Voltage Protection, 

but the unit will continue to 

operate. If the input voltage drops  

to 10.0V or less, the inverter will 

shut down to protect itself, the 

meter will continue to flash as 

shown, and an alarm will sound.
To restore normal operation, return 

the DC input voltage to at least 

12V. The inverter will automatically 

return to normal operation.
 High Voltage Protection – If the 

DC input voltage rises above 15.0V, 

the inverter will shut down to protect 

itself, the meter will flash as shown 

to indicate Over Voltage Protection, 

and an alarm will sound.
To restore normal operation, return 

the DC input voltage to less than 

15V. The inverter will automatically 

return to normal operation.

High Voltage

Low Voltage

High Temperature

Over Temperature Protection –  

If the internal inverter temperature 

rises above the alarm threshold, 

the meter will flash as shown, an 

alarm will sound to indicate Over 

Temperature Protect, and the unit 

will continue to operate. If the 

internal temperature rises to 40ºC 

(104ºF), the inverter will shut down 

to protect itself, the meter will 

flash as shown and the alarm will 

continue to sound.

NOTE Internal inverter temperature 

can rise due to being operated in a 

high heat environment or due to the 

fan or vents being blocked during 

operation (even in relatively cool 

outside air).
To restore normal operation, turn 

the unit Off and allow it to cool. 

The inverter will automatically 

return to normal operation after  

it has cooled.

Intro

Operation

Customer

Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Operating Indicators

CPI2590_MANL.indd   16-17

12/5/14   2:11 PM

Summary of Contents for CPI2590

Page 1: ...owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance services For Assistance in the U S A Automated Help Desk English o...

Page 2: ...Notes Notice Main Icons Secondary Icons Caution Warning Installation Contents Introduction Our Thanks to You A1 Customer Assistance A1 Product Features A2 Important Safety Information 1 Quick Evaluat...

Page 3: ...g and using it Special attention must be paid to the CAUTION and WARNING statements in the manual CAUTION Statements specify conditions which could cause damage to the unit or other equipment WARNING...

Page 4: ...nd night lights that can be plugged directly into an AC receptacle to recharge 2 Certain battery chargers for battery packs used in hand power tools These chargers have a WARNING label stating that da...

Page 5: ...es for a full 2500 Watt load 3 A test load that can be plugged into the AC receptacle on the inverter for short term testing at a low power level The following cables are recommended for testing low p...

Page 6: ...ce compartment Overheating may result CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will not work with a 6 volt battery and will be damaged if i...

Page 7: ...n on the inverter to the off position If the power source is a DC power supply switch it off as well 2 Connect cables to the Power Input Terminals on input end of the inverter The red terminal is posi...

Page 8: ...m the Positive Red Terminal of the inverter to the Positive Terminal of the power source the battery s main fuse or the battery selector switch if you are using one Make a secure connection NOTE Pleas...

Page 9: ...dary Icons Caution Warning Installation Installation Intro Operation Customer Assistance Warranty Notes Notice Main Icons Secondary Icons Caution Warning Installation Installation Laptop 100 watts x 2...

Page 10: ...the unit s power status and alarms for conditions that could cause it to shut down Power on The Voltage Input and Power Output indicators automatically toggle between input and output values at three...

Page 11: ...wn to indicate Over Voltage Protection and an alarm will sound To restore normal operation return the DC input voltage to less than 15V The inverter will automatically return to normal operation High...

Page 12: ...the input voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 5V 0 5V This protects the inverter against excessive input voltage Although the inverter has protect...

Page 13: ...ivery to the Cobra Factory Service department accompanied by proof of the date of first consumer purchase such as a duplicated copy of a sales receipt You must pay any initial shipping charges require...

Page 14: ...ransit to Cobra Factory Service Cobra Electronics Corporation 6500 West Cortland Street Chicago Illinois 60707 USA 6 If the power inverter is in warranty upon receipt of your power inverter it will ei...

Page 15: ...24 Notes...

Reviews: