100-M0167X2
7 of 21
GMS Inc. doing business as Cobham Tactical Communications and Surveillance
www.cobham.com/tcs
2.
ABSOLUTE MAX RATINGS
Table 1 – ABSOLUTE MAX RATINGS
MAX MOMENTARY RF INPUT COFDM
6 dBm
MAX SUPPLY VOLTAGE
35 Vdc
MAX CONTINUOS COFDM PWR
2 W
MAX CONTINUOUS FM PWR
3 W
MAX PA_ENABLE VOLTAGE
6.5 Vdc
CAUTION: 2-3 dBm is the typical input PWR for operation at 2 W. The PA will survive a momentary 3 dB
overdrive. Larger overdrives will trigger the protection circuit (see section 4.2)
3.
SPECIFICATIONS
Table 2 – General Specifications:
Parameter Specification
DC input voltage (Vdc)
9-32
Mechanical Dimension
(without heat-sink)
2.1 "L x 3.0 "W x 0.6 "H
5.3 cm x 7.6 cm x1.52 cm
Weight
lbs
0.300
grams
136
Base-plate Temperature
-20 °C to + 70 °C
Operating Humidity
95% Non-condensing
Control Connector (Header)
9pin 1.25mm JST
SM09B-GHS-TB
FAULT 2
PIN 1
FAULT 1
PIN 2
MODE SELECT
PIN 3
+5 VDC (OUTPUT)
PIN 4
PA ENABLE (3-5Vdc)
PIN 5
Vcc (9-32Vdc)
PIN 6
Vcc (9-32Vdc)
PIN 7
GND PIN
8
GND PIN
9
RF Connectors
SMA female
NOTES:
To select High Efficiency MODE (LOW CURRENT) leave Pin 3 open.
To select High Linearity MODE (HIGH MER) connect Pins 3 and 4. Or connect 3-5 Vdc to Pin3.
PA ENABLE is LVTTL compatible.
Pins 8 and 9 are internally connected to chassis.