36
Type ‘p’ messages for SI
Function
R/W
Block
Command
Data
Type
PCR PID
r/w
p
cpd
0 = default
Other = value
int
PMT PID
r/w
p
mpd
0 = default
Other = value
int
Video
Stream ID
r/w
e
sid
0 = default
Other = value
int
Audio
Stream ID
r/w
a
sid
0 = default
Other = value
int
Transport
Stream
Version
r/w
t
svr
0 = default
Other = value
int
Provider
Name
r/w
g
pro
0 = default
Other = value
string
Type ‘d’ messages for Data commands
Function
R/W
Block
Command
Data
Type
Data On/Off
r/w
d
inp
1 byte
0 = Off
1 = On
2 = On (even parity)
3 = On (odd parity)
int
Input Data
Baudrate
r/w
d
bau
1 byte
0 = 1200 baud
1 = 2400 baud
2 = 4800 baud
3 = 9600 baud
4 = 19200 baud
5 = 38400 baud
6 = 57600 baud
(note 57600 is not
supported in DVB-T
modes)
7 = 115200 baud
int
Data PID
r/w
d
pid
0 = default
Other = value
int
Metadata
Enable
r/w
m
eta
1 byte
0 = Off
1 = On
int
Metadata
PID
r/w
m
pid
0 = default
Other = value
int