Internal Switch Settings
The 8020 has additional configuration controls via internal register rotary selection and input (up/down)
switches. To access these controls, disconnect power while removing the bottom cover and locate two
rotary switches (S5, S6) and two push button (S7-UP, S8-Down) switches and reapply power.
Default convention: Use S7 (UP) to increment or turn function on. Use S8 (Down) to decrement or turn
function off. On most functions, pressing both S7 & S8 (Up & Down) restores the default mode.
To save user settings, select 99 and press either the Up or Down switch.
S5S6
00: Normal User Mode
Restore to 00 prior to device use
10-19: Reserved
20-29: Reserved
30-39: Reserved
57: Enable over sampling on Encoder
Default is on
58: Enable HD VBI
Default is on
59: Enable SD VB
Default is on
60: User Reticule Mode Vert bars size H
61: User Reticule Mode Vert bars thickness
62: User Reticule Mode 4x3 box Horz size
63: User Reticule Mode 4x3 box Vert size
64: User Reticule Mode 4x3 box Horz Thickness
65: User Reticule Mode 4x3 box Vert Thickness
66: User Reticule Mode 16x9 box Horz size
67: User Reticule Mode 16x9 box Vert size
68: User Reticule Mode 16x9 box Horz Thickness
69: User Reticule Mode 16x9 box Vert Thickness
70: User Reticule Mode Cross Horz size
71: User Reticule Mode Cross Vert size
72: User Reticule Mode Cross Horz Thickness
73: User Reticule Mode Cross Vert Thickness
74: User Reticule Mode Y Level
75: User Reticule Mode Cb Level
76: User Reticule Mode Cr Level
74-83, 86: Reserved
84: HD Analog Embedded SYNC
UP = tri-level (default)
Down = bi-level
85: SD-SDI/Analog Dejitter
UP = Filter ON
Down = Filter OFF
88: Restore factory defaults
89-98: Reserved
99: Save current values
Make certain that the rotary switches are restored to 0, 0 before re-installing the bottom cover.