3
BBG-1070-QS Function Menu List and Descriptions
3-48
BBG-1070-QS PRODUCT MANUAL
BBG1070QS-OM (V1.8)
GPI Setup Controls
Provides controls for setting up to 16 “virtual GPIs”
using the up to five discrete GPI inputs. The virtual GPIs
can in turn be used for attribute control such as tally
lamp activation, borders, and ident text (in conjunction
with the Event Action tab controls).
Table 3-1
BBG-1070-QS Function Menu List — continued
Up to five GPI inputs are available which can be used as direct or logic statement control inputs. Additionally, up to 256 VGPIs
(virtual GPIs) can be received via certain automation system via the network connection.
In examples here, GPI Condition 2 goes active when triggers defined as other than Don’t Care become true (in this case, the
GPI 1 and GPI 2 2 conditions shown).
In the GPI Condition 15 example shown here, the GPI inputs are not used (set to Don’t Care), while when VGPI# 15 goes true,
GPI Condition 15 becomes active.
GPI Condition 1 thru GPI Condition 16 defined here are in turn used with the Event Actions page to provide tally, border, and
other attributes control based off of GPI inputs received. (See Event Actions Setup Controls (p. 3-49) for instructions on setting
up action triggering controls.)
GPI 1 thru GPI 4 definers have drop-down which allow setting the logic
associated with the input:
Open = pullup HI
Closed = pulldown LO
Open->Closed = falling-edge trigger
Closed->Open = rising-edge trigger
• Unused GPI inputs should be set to “Don’t Care”
Make certain GPI inputs are in accordance with GPI Inputs in Technical Specifications, Chapter 1. Introduction.