a. When lighting , open both firedoors and place paper 

and sticks with a small quantity of fuel onto the 3 
bottomgrate. Ignite fuel and lock both firedoors with 
firedoor air slides fully opened i.e. air slide levers 
moved away from centre of firebox.

b. With the appliance under fire, check for soundness 

of seals/joints and that the flue functions correctly in 
permitting all smoke and fumes to be vented through
the chimney.

After completing the installation, the Heating Contractor
should demonstrate to the user, the operation of the fire
e.g. primary air setting lever, the method of riddling and
the lowering of the throat plate for cleaning purposes as
well as the routine flue cleaning method.

Ensure the Operating Instructions are left in the
possession of the user.

Weight of complete stove 227Kg

Bottomgrate bars - there are eight grate bars of one
type and seven of another.

The eight bars occupy the ends and intermediate
positions. The seven bars fit between these.

See that they are properly placed on the cross front
firebar and move freely when riddled.

Flue Pipe

Lengths of 150mm diameter black painted C.I. flue
pipes are available through your local stockists.

Replacement parts if required are available through your
local stockist.

4

GENERAL INFORMATION

COMMISSIONING

TESTING 

AFTER COMMISSIONING

With Aga-Rayburn’s policy of continuous product improvement, the
Company reserves the right to change specifications and make
modifications to the appliance described and illustrated at any time.

Manufactured By
Aga-Rayburn
Station Road, Ketley, Telford, Shropshire, TF1 5AQ

Telephone (01952) 642000

Fax (01952) 641961

For further advice or information contact
your local distributor/stockist

www.aga-rayburn.co.uk

www.agacookshop.co.uk

Reviews: