8) Please protect short circuit by installation circuit breaker into the main power cable of
the compressor.
9) To prevent electric leakage, please connect connector to the main terminal block.
10) Refer to following table for the wire thickness and applicable circuit breaker.
11) Always meet NEC and/or local codes, consult your distributor
4.1 Trial Operation
1) Please make sure the power cable and connector are connected.
2) Please make sure the drain valve is closed.
3) Turn "ON" the power circuit breaker. <Fig. 9>
4) Please make sure the power lamp has been turned on. At the same time, check if the alarm lamp
is turned off. If the temperature sensor code is detached, alarm lamb will be turned on.
At this time, please reconnect temperature sensor.<Fig. 8>
COAIRE, Div. of Quietside Corporation
12
Circuit Breaker(Amp)
Fuse Type B
230V / 460V
CSOF-S3PL(H)
30A
15 / 10
CSOF-S5PL(H)
30A
30 / 15
Models
4. OPERATION METHOD
<Fig. 9>
<Fig. 10>