110 VOLT AMP RATING
Coffee Maker ....................................8.3 amps
Refrigerator-Dometic..................2.7 amps
Converter ..........................................8.0 amps
Refrigerator-Norcold ..................2.9 amps
Food Processor..................................5.6 amps
Roof Air Conditioner-Cool.........13.3 amps
Electric Skillet ...................................6.0 to 12.0 amps
Roof Air Conditioner-Heat ........16.0 amps
Hair Dryer .........................................9.0 to 12.0 amps
Television.....................................1.5 amps
Ice Maker ..........................................2.9 amps
Toaster .........................................8.0 to 10.0 amps
Microwave..........................................10.0 amps
Vacuum Cleaner .........................6.2 amps
Microwave/Convection Oven ..........13.0 amps
VCR Tuner...................................2 amps
Power Center ....................................5.8 amps
Washer/Dryer .............................14.6 amps
Chest Freezer ....................................6 amps
12 VOLT AMP RATING
Air Bag Compressor .........................2.0 amps
LP Detector .................................1 amps
Air Horn Compressor.......................12.0 amps
Interior Lights:
Antenna Booster ...............................8.0 amps
Aisle Light ...................................1 amps
Auxiliary Auto Heater ......................8.0 amps
Bar Light .....................................2.8 amps
Back-up Camera................................1.8 amps
Decorator Ceil. (per bulb).........9 amps
Back-up Monitor ...............................2.0 amps
Fluorescent Light........................1.5 to 2.1 amps
Ceiling Fan ........................................4.0 amps
Map Light....................................1.0 amps
Cruise Control ..................................(16 milliamps)
Pancake Light .............................1.4 amps
Dash AC/Heater...............................18.0 amps
Wall Lamp (per bulb) ................9 amps
Defroster Fan ....................................1.8 amps
Leveling Jacks..............................4.0 to 300.0 amps
Electric Mirror-Adjust.......................4.0 amps
Power Roof Vent .........................1.4 amps
Electric Mirror-Defrost .....................2.8 amps
Power Seat ...................................12.0 amps
Electric Step ......................................12.0 amps
Power Window ............................12.0 amps
Radio-CB/Stereo ..............................4.0 to 4.6 amps
Exterior Lights:
Clearance Light (Ea.) ......................1 amps
Refrigerator-Dometic..................14.6 to 13.8 amps
Headlights-Low Beam.......................16.0 amps
Refrigerator-Norcold ..................1.8 amps
Headlights-High Beam .....................24.3 amps
Security System ...........................1.0 amps
Landing Lights..................................5.5 amps
LED Off .......................................(20 milliamps)
Parking Lights...................................9.4 amps
LED Armed .................................(30 milliamps)
Porch Light .......................................1.1 amps
Television.....................................4.9 amps
Spot Light..........................................7.0 amps
VCR Recorder/Player.................2.0 amps
Storage Comp. Light (Ea.) ..............1.4 amps
Water Heater...............................1.0 amps
Taillights ............................................2.4 amps
Water Pump ................................4.0 amps
Furnace..............................................11.0 amps
Windshield Washers....................3.0 amps
Generator (Cranking)......................300.0 amps
Windshield Wipers (Wet)...........8.0 amps
CO Detector......................................1 amps
Range Hood ................................2.3 amps
POWER CENTER & DISTRIBUTION PANEL
This is the "breaker box" of your Coachmen recreational vehicle. All 120-volt circuit breakers are located
here as well as most of the 12-volt fuses.
✔
At the beginning of camping season, inspect all breakers and fuses with shore line plugged in.
✔
Turn each breaker OFF and back ON. Replace breaker with one of the same rating if breaker trips.
WARNING: DO NOT
use a larger rated amperage breaker. Doing so will increase the risk of an electrical
fire.
✔
Inspect 12-volt fuses, replace if necessary. Always use a replacement fuse of the same rating.
WARNING: DO NOT
use a larger rate amperage fuse. Doing so will increase the risk of an electrical fire.
33
ELECTRICAL
Summary of Contents for Aurora
Page 4: ...2 ...
Page 10: ...8 ...
Page 14: ...12 ...
Page 16: ...14 ...
Page 18: ...16 ...
Page 20: ...18 ...
Page 22: ...20 ...
Page 24: ...22 ...
Page 26: ...24 ...
Page 28: ...26 ...
Page 30: ...28 ...
Page 42: ...40 ...
Page 46: ...44 ...
Page 50: ...48 ...
Page 52: ...50 ...
Page 55: ...53 MAINTENANCE CHARTS ...
Page 56: ...54 MAINTENANCE CHARTS ...
Page 57: ...55 MAINTENANCE CHARTS ...
Page 58: ...56 MAINTENANCE CHARTS ...
Page 59: ...57 MAINTENANCE CHARTS ...
Page 60: ...58 MAINTENANCE CHARTS ...
Page 70: ...68 TROUBLESHOOTING ...
Page 77: ...75 APPENDIX A POWER GEAR SLIDE OUT ROOM TOWABLES ...
Page 78: ...76 APPENDIX A POWER GEAR SLIDE OUT BEDROOM TOWABLES ...