Specifications 

TS

System

 

TecPen

 

MAP

 

O2

 

Measurement

 

range

 

0

5%

 

Range

 

Accuracy

 

0

0.5%

 

±

 

2%

 

Mev**

 

0.5

2.5%

 

±3%

 

Mv*

 

2.5

5%

 

±5%

 

Mv*

 

Resolution

 

0.001%

 

Response

 

time

 

at

 

25°C/

 

77°F

 

<150ms

 

Pump

 

flow

 

max.

 

67

 

mL

 

Temp.

 

range

 

Min./Max

 

 ‐

10°C/

 

+60°C

 

14°F/140°F

 

Medium

 

Gas

 

Power

 

supply

 

5V

 

USB

 

and

 

LiPo

 

battery

 

Rechargeable

 

battery

 

lifetime

 

> 3

 

hours

 

per

 

charge

Data

 

Interface

 

USB

 

Temperature

 

compensation

 

10

30°C

 

50

86

 

°F

 

Display

 

OLED

 

Display

 

Cleaning

 

housing

 

no

 

organic

 

solvents.

 

40%

 

EtOH

 

Parts

 

touching

 

sample

 

St.1.4404/

 

PTFE/

 

Glas

 

Case

 

aluminium

 

anodized

 

Protection

 

IP65

 

Full

 

service

 

interval

 

by

 

Manufacturer

 

(includes

 

necessary

 

retrofitting)

 

3

 

years

 

Life

 

time

 

of

 

sensor

 

spot

  

(protective

 

atmosphere;

 

0

‐ 

40°C)

 

24

 

months

 

Sensor

 

cap

 

replacement

 

interval

 

2

 

years

 

Recommended

 

zero

point

 

adjustment

 

interval

 

by

 

customer

 

6

 

months

 

Warranty

 

1

 

Year

 

ex

 

works

 

**Mev

 

=

 

measured

 

end

 

value

 

*Mv

 

=

 

measured

 

value

TecSense sensors are CE, FCC, IC, KC and MIC marked, meet the requirements of ASTM F2714-
08, and the European and Canadian standards for food safety. The company is DIN ISO 
9001/2015 certified. 

Summary of Contents for TecPen MAP

Page 1: ...TecPen MAP Oxygen Analyzer User Manual Version 11 ...

Page 2: ...enu Options 8 Change Data File Format Recipes 8 Set Date and Time 8 View Measurement Data Display 8 View Device Status 8 Saving Data 9 Default Operation 9 Output Data File Format 9 Exporting Saved Data Files 9 USB Data Safety 9 Customizing the Output Data File 10 Zero Point Adjustment 10 Maintenance 11 Cleaning 11 Battery 11 ISO Certification 11 Device Status Codes 11 Troubleshooting Guide 12 Spec...

Page 3: ...ake a septum and place it on the package Make sure that that the septum is placed on a place where enough gas is available to make the test 9 Insert the needle into the gas filled space to be measured 10 Press START immediately after piercing the sample 11 The MEAS will appear on the display The oxygen value will change continuously during measurement 12 If appears your measured value is outside t...

Page 4: ...ectivity This makes it an excellent tool for Food packaging in protective gas atmosphere MAP packaging Headspace of vials cell breeding vessels infusion containers syringes Micro bioreactor systems Package Contents Quantity Item 1 TecPen 1 Case 2 Particulate Filters 2 Sampling needle 25 0 8 1 USB Cable 1 USB Protection Cover 1 USB Flash Drive 1 Instruction Manual 12 Septum 1 Flexible Extension 1 C...

Page 5: ...surement 2 OLED Display 3 PWR Power LED Lights up when the device is switchedon 4 BT LED Lights up when charging and turned on 5 Memory Button saves measurement 6 ON OFF Button press briefly switch on device hold down switch off 7 USB Port 8 Sampling Gas Inlet 9 Gas Outlet ...

Page 6: ...he TecPen shows the battery status and a value of This is a placeholder and not an actual measurement result 1 After turning it on let the TecPen warm up for 2 minutes to insure accuracy 2 The TecPen can only be switched on when it is not connected to the charging cable 3 If no buttons are pressed within five minutes the TecPen will switch itself off The unit can also be switched off by pressing t...

Page 7: ...ery level measured value Temporary Memory Log Indicator Indicator for current measurement Screen 2 Current Recipe Settings Consecutive internal number product name EAN code Screen 3 Date Time date time 24 hour clock Screen 4 Measurement data display amplitude life temperature Screen 5 Info screen serial number device status code Screen 6 Zero point calibration Select option YES NO NOTE 100 Nitroge...

Page 8: ...pears 2 Press START for two seconds 3 The year will be underlined 4 To scroll down or decrease number press SAVE 5 To scroll up or increase number press START 6 After setting the year press START for two seconds 7 The year is saved when the month is underlined 8 Repeat steps 4 7 until everything is set 9 Press SAVE for 2 seconds to save the settings View Measurement Data Display 1 Hold the SAVE bu...

Page 9: ...defined Product_Oxygen_Value 0 53472 range 0 5 Amplitude 14016 signal strength for error checking Tau 64 610248 signal life for error checking Temperature C 25 187500 Centigrade only Battery_Level 86 range 0 100 Device Status 0 Normal see device status codes Exporting Saved Data Files 1 Press the ON OFF buttonto turn on the unit 2 Connect the TecPen to a PC using the supplied USB cable 3 The TecPe...

Page 10: ...o calibrate the TecPen it must be first be purged of any remaining gas from previous use by running the pump for several seconds until the device is filled with pure nitrogen Follow the steps below 1 Connect the TecPen to pure nitrogen at 1L min flow and perform 2 measurements to insure the device is completely devoid of oxygen 2 Press and hold the START button then press the SAVE button untilthe ...

Page 11: ...o decrease more quickly the battery to overheat or become defective Should the charging capacity decrease unusually quickly within one year or with a maximum of 300 charge cycles whichever is reached first due to a production error please contact CO2Meter ISO Certification The instrument must be returned annually to the manufacturer for recalibration in accordance with ISO 9000 certification Devic...

Page 12: ...ted to a power outlet the BT light does not light up while the device is charging 7 The device is connected to the Computer but I cannot find it You must switch on the device before connecting to the computer If the device is switched on but you cannot find it check for available COM ports 8 The measured value is not saved Did you press the LOG button Did you observe the LOG sign on the display If...

Page 13: ...ousing no organic solvents 40 EtOH Parts touching sample St 1 4404 PTFE Glas Case aluminium anodized Protection IP65 Full service interval by Manufacturer includes necessary retrofitting 3 years Life time of sensor spot protective atmosphere 0 40 C 24 months Sensor cap replacement interval 2 years Recommended zero point adjustment interval by customer 6 months Warranty 1 Year ex works Mev measured...

Page 14: ...warranty starting from the date it was shipped to the buyer The TecPen sensor cap comes with a 90 day warranty For more information visit our website https www co2meter com pages terms conditions Contact Us If the troubleshooting guide above does not help you solving your problem or for more information please contact us using the information below Sales CO2Meter com 877 678 4259 M F 8 30am 5 00pm...

Reviews: