Sampling Data Logger User Manual

 

CO2Meter

 

 

 

PAGE 

9

of 

16

 

Powering

 

the

 

Unit

 

These

 

meters

 

have

 

a

 

switch

 

on

 

the

 

front

 

dedicated

 

to

 

enabling/disabling

 

data

 

logging

 

(right

 

on

 

Figure

 

above)

 

and

 

another

 

dedicated

 

to

 

powering

 

the

 

unit

 

(left

 

on

 

Figure

 

above).

 

As

 

long

 

as

 

the

 

unit

 

is

 

connected

 

to

 

an

 

appropriate

 

power

 

source

 

and

 

the

 

power

 

switch

 

is

 

in

 

its

 

ON

 

position,

 

the

 

unit

 

will

 

be

 

operating

 

properly.

 

LCD

 

Display

 

(if

 

applicable)

 

The

 

Liquid

 

Crystal

 

Display

 

(LCD)

 

screen

 

shows

 

the

 

following

 

features:

 

 

CO2

 

in

 

parts

per

million

 

(ppm)

 

for

 

1%

 

and

 

5%

 

models

 

 

CO2

 

in

 

percentage

 

format

 

(##.##%)

 

for

 

30%,

 

65%,

 

100%

 

 

Logging

 

On/Off

 

 

Percentage

 

of

 

memory

 

free

 

Usage

 

(Pump

 

only)

 

In

 

order

 

to

 

use

 

the

 

unit,

 

hoses/tubing

 

must

 

be

 

attached

 

to

 

the

 

inlet

 

and

 

outlet

 

fittings

 

on

 

the

 

front

 

of

 

the

 

unit.

 

The

 

pump

 

will

 

draw

 

air

 

from

 

the

 

inlet

 

in

 

a

 

vacuum

 

configuration,

 

push

 

it

 

through

 

the

 

sensing

 

chamber,

 

and

 

exhaust

 

the

 

air

 

out

 

through

 

the

 

outlet.

 

Closed

 

Loop

 

Operation

 

 

Figure

 

5:

 

Closed

 

loop

 

sampling

 

setup

 

Open

 

Loop

 

with

 

Environmental

 

Exhaust

 

 

Figure

 

6:

 

Opened

 

loop

 

sampling

 

setup

 

Summary of Contents for CM-0052

Page 1: ...Copyright 2016 CO2Meter Inc All Rights Reserved User Manual CO2 Sampling Data Logger NEMA4 Models CM 0052 CM 0152 CM 0154 CM 0132 CM 0153 CM 0155...

Page 2: ...8 POWERING THE UNIT 9 LCD DISPLAY IF APPLICABLE 9 USAGE PUMP ONLY 9 Closed Loop Operation 9 Open Loop with Environmental Exhaust 9 THEORY OF OPERATION 10 0 1 and 0 30 Units Only 10 CALIBRATION 11 0 1...

Page 3: ...ue opportunity to understand educate and provide product solutions that meet the customers needs while exceeding their expectations for reliability and service Our continued product innovation in comb...

Page 4: ...ns basic safety precautions should always be followed when using electrical appliances including the following 1 READ ALL INSTRUCTIONS BEFORE USING THIS METER 2 INSTALL GasLab SOFTWARE BEFORE CONNECTI...

Page 5: ...dity out Use anywhere humidity is very high 95 SKU CM 0103 GasLab Software IMPORTANT MAKE SURE TO INSTALL SOFTWARE BEFORE CONNECTING YOUR METER TO YOUR COMPUTER Minimum System Requirements To utilize...

Page 6: ...manual in PDF from this page Please read the GasLab s user manual carefully to become more familiar with how the software works so that you can get the maximum benefit from this useful tool Install t...

Page 7: ...uts and Cable Legend Pin Wire Color Color Legend Description 1 Brown CO2 4 20mA 2 Blue N O Relay 3 White CO2 4 20mA 4 Green RS 485 Ground 5 Pink N C Relay 6 Yellow COM Relay 7 Black Power Ground 8 Gre...

Page 8: ...uration These meters feature an internal memory capable storing data when not attached to a personal computer These units will allow you to simultaneously read and store CO2 concentration level data D...

Page 9: ...licable The Liquid Crystal Display LCD screen shows the following features CO2 in parts per million ppm for 1 and 5 models CO2 in percentage format for 30 65 100 Logging On Off Percentage of memory fr...

Page 10: ...hese units The primary contributor to sensor drift is the normal and unavoidable aging of the infrared light source within the sensor The ABC algorithm allows the CO2 sensor to dynamically shift its C...

Page 11: ...s follow a single point calibration routine that effectively shifts the zero point of the CO2 sensor Attach calibration gas to the unit and connect it to a personal computer Open the calibration scree...

Page 12: ...pm 5 Disconnect the calibration gas and wait 25 seconds The newly displayed data will now reflect the new sensor calibration If the sensor is still operating outside of its specified range repeat this...

Page 13: ...correct concentration level then close the window by clicking on the Save button NOTE DO NOT ADJUST THE SPAN VALUE Troubleshooting guide Symptom Issue Possible Cause Resolution Device Sensor is not re...

Page 14: ...C Minimum Voltage 18VDC Power Consumption 1Watt avg pump running Sensor Ratings Life Expectancy 15 years Maintenance Interval No maintenance required Warm up Time 1 min instant measurements Pump Chara...

Page 15: ...irs by you or by a third party No employee or reseller of CO2Meter com s products may alter this warranty verbally or in writing Liability All liabilities under this agreement shall be limited to the...

Page 16: ...ng Data Logger User Manual CO2Meter PAGE 16 of 16 Contact Us We are here to help For information or technical support please contact us support co2meter com 386 256 4910 Technical Support 386 872 7665...

Reviews: