background image

Sampling Data Logger User Manual

 

CO2Meter

 

 

 

PAGE 

4

of 

16

 

 
 
 
 

 
 

WARNING!

 

Install

 

GasLab®

 

software

 

before

 

connecting

 

your

 

CO2Meter

 

product(s)

 

to

 

your

 

computer.

 Failure to do so may affect the ability for GasLab® to 

detect your meter/sensor. If this happens, please follow the instructions 

shown in the TroubleShooting Guide of this manual. 

Important

 

Safeguards

 

To

 

reduce

 

the

 

risk

 

of

 

fire,

 

electrical

 

shock

 

and/or

 

injury

 

to

 

persons,

 

basic

 

safety

 

precautions

 

should

 

always

 

be

 

followed

 

when

 

using

 

electrical

 

appliances,

 

including

 

the

 

following:

 

1.

 

READ

 

ALL

 

INSTRUCTIONS

 

BEFORE

 

USING

 

THIS

 

METER.

 

2.

 

INSTALL

 

GasLab®

 

SOFTWARE

 

BEFORE

 

CONNECTING

 

METER

 

TO

 

A

 

COMPUTER.

 

3.

 

Use

 

only

 

the

 

included

 

power

 

supply

 

to

 

operate

 

this

 

meter.

  

4.

 

Make

 

sure

 

that

 

the

 

tubes

 

are

 

securely

 

attached

 

to

 

the

 

meter

 

before

 

sampling

 

a

 

closed

 

environment

 

(CM

0045

NM

SP

 

model

 

only).

 

5.

 

Do

 

not

 

operate

 

with

 

an

 

obstructed

 

sample

 

path

 

(CM

0045

NM

SP

 

model

 

only).

 

6.

 

Do

 

not

 

operate

 

this

 

meter

 

if

 

the

 

enclosure

 

is

 

opened.

 

7.

 

Do

 

not

 

operate

 

the

 

device

 

if

 

it

 

is

 

malfunctioning.

 

 

SAVE

 

THESE

 

INSTRUCTIONS!

 

 

 

Summary of Contents for CM-0052

Page 1: ...Copyright 2016 CO2Meter Inc All Rights Reserved User Manual CO2 Sampling Data Logger NEMA4 Models CM 0052 CM 0152 CM 0154 CM 0132 CM 0153 CM 0155...

Page 2: ...8 POWERING THE UNIT 9 LCD DISPLAY IF APPLICABLE 9 USAGE PUMP ONLY 9 Closed Loop Operation 9 Open Loop with Environmental Exhaust 9 THEORY OF OPERATION 10 0 1 and 0 30 Units Only 10 CALIBRATION 11 0 1...

Page 3: ...ue opportunity to understand educate and provide product solutions that meet the customers needs while exceeding their expectations for reliability and service Our continued product innovation in comb...

Page 4: ...ns basic safety precautions should always be followed when using electrical appliances including the following 1 READ ALL INSTRUCTIONS BEFORE USING THIS METER 2 INSTALL GasLab SOFTWARE BEFORE CONNECTI...

Page 5: ...dity out Use anywhere humidity is very high 95 SKU CM 0103 GasLab Software IMPORTANT MAKE SURE TO INSTALL SOFTWARE BEFORE CONNECTING YOUR METER TO YOUR COMPUTER Minimum System Requirements To utilize...

Page 6: ...manual in PDF from this page Please read the GasLab s user manual carefully to become more familiar with how the software works so that you can get the maximum benefit from this useful tool Install t...

Page 7: ...uts and Cable Legend Pin Wire Color Color Legend Description 1 Brown CO2 4 20mA 2 Blue N O Relay 3 White CO2 4 20mA 4 Green RS 485 Ground 5 Pink N C Relay 6 Yellow COM Relay 7 Black Power Ground 8 Gre...

Page 8: ...uration These meters feature an internal memory capable storing data when not attached to a personal computer These units will allow you to simultaneously read and store CO2 concentration level data D...

Page 9: ...licable The Liquid Crystal Display LCD screen shows the following features CO2 in parts per million ppm for 1 and 5 models CO2 in percentage format for 30 65 100 Logging On Off Percentage of memory fr...

Page 10: ...hese units The primary contributor to sensor drift is the normal and unavoidable aging of the infrared light source within the sensor The ABC algorithm allows the CO2 sensor to dynamically shift its C...

Page 11: ...s follow a single point calibration routine that effectively shifts the zero point of the CO2 sensor Attach calibration gas to the unit and connect it to a personal computer Open the calibration scree...

Page 12: ...pm 5 Disconnect the calibration gas and wait 25 seconds The newly displayed data will now reflect the new sensor calibration If the sensor is still operating outside of its specified range repeat this...

Page 13: ...correct concentration level then close the window by clicking on the Save button NOTE DO NOT ADJUST THE SPAN VALUE Troubleshooting guide Symptom Issue Possible Cause Resolution Device Sensor is not re...

Page 14: ...C Minimum Voltage 18VDC Power Consumption 1Watt avg pump running Sensor Ratings Life Expectancy 15 years Maintenance Interval No maintenance required Warm up Time 1 min instant measurements Pump Chara...

Page 15: ...irs by you or by a third party No employee or reseller of CO2Meter com s products may alter this warranty verbally or in writing Liability All liabilities under this agreement shall be limited to the...

Page 16: ...ng Data Logger User Manual CO2Meter PAGE 16 of 16 Contact Us We are here to help For information or technical support please contact us support co2meter com 386 256 4910 Technical Support 386 872 7665...

Reviews: