NOTE:

  Unit 

must 

be vented  

                        to outside of the building. 

 
Prepare soffit or other surface for mounting the hood by 
using a minimum 3/4 inch thick plywood mounting plate 
prepare with the FIG-1. NOTE THAT A MINIMUM 2-3/4 
inch soffit overhang is required to achieve a sufficient 
structural support base. The overhang, of course, can be 
greater than 2-3/4. Note the position of the hood front 
relative to the opening in the mounting plate refer to 
FIG-1. 

 

 
Provide an adequate support structure for attaching the 
prepared mounting plate to ceiling structure. Local 
building codes should be adhered to at all times. 
Remember that your new hood is of sufficient weight that 
an adequate support structure is necessary. 
 
 
Attach and secure the transition to the hood with #6 x 3/8 
inch sheet metal screw after inserting one flange of the 
transition under the hood flange (Detail instruction is 
included with transition). Tape all joints prior to installing 
the hood, being careful not expose tape beyond outer edge 
of hood top flange. Attach the hood to the prepared 
mounting plate and soffit using # 10 wood screws. Holes 
are located in the top panel 

 HINT: marking and pilot 

drilling these holes in the mounting plate will aid 
installation. The # 10 wood screws should be a minimum 
of 3/4 inches long if no other surfaces is located between 
the mounting base and hood. If drywall or other surfaces 
are positioned between the hood and mounting base the 
#10 wood screws must be 

longer to provide a full 3/4” 

engagement of the screw into the mounting plate. 
 
 
 
 
 
 

HINT:

 If you find vibration noise is present because of 

cabinet/mounting structure use additional screws, in holes 
available to rigidize mounting. 
 
Connect 120 volts 

 15 amp, 60 Hz power supply through 

the conduit hole in the top of hood, connecting to pigtail in 
hood junction box, white to white, black to black and 
connect green ground wire to power supply ground wire per 
local codes. The VEN100E/150E ventilator will require 
revision of some wiring in the hood receptacle box and 
possible modification of air discharge opening 

 See 

VEN100E/150E instructions. 
     

NOTE: VEN150E requires a 20AMP Power Supply. 

 

The recommended height from counter top or cooking 
surface to the bottom edge of the hood is 30 to 36 inches.

 

Hood is recommended for use over domestic gas or electric 
appliances. Not recommended for use over solid fuel fire 
appliances 
 
 
After installing the hood, install the internal blower (see 
FIG-2) unit by positioning the blower into bracket- A, 
notched blower bracket will center blower, rotating into 
position against hood top, and securing with #8 sheet metal 
screws via bracket 

 B. To ease assembly you should 

predrive the #8 sheet metal screws before installing the 
blower. If the remote ventilator is used see related 
instructions. 
 

CAUTION:

 The hood is of sufficient weight that two 

Installers are recommended to prevent injury or damage to 
the hood in handling. 
 
 
Turn the power on at the service entrance and check the 
operation of the controls. 
 

NOTE:

 Be sure that all dampers (Not Supplied) are 

operating properly and are free to open.

 
 
 

BACKDRAFT DAMPER

: It is recommended that a backdraft damper be used 

in all installations. In cold weather installations it is necessary to use a backdraft 
damper to minimize backflow of cold air into room. A non-metallic thermal 
break should also be installed to minimize conduction of outside temperatures 
through the ductwork. The thermal break should be located as close as possible 
to where the ducting enters the heated portion of the house. 

SAFTY WARNING: 

Turn off power circuit at 
the service entrance and 
lockout panel before 
wiring the range hood. 

Summary of Contents for WindCrest PSL

Page 1: ... Lock Service Disconnecting Means to Prevent Power From Being Switched On Accidentally When The Service Disconnecting Means Cannot be Locked Securely Fasten A Prominent Warning Device Such As A Tag To The Service Panel CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE FOR DUCTED FANS DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILING OR INTO ATTICS...

Page 2: ...er supply through the conduit hole in the top of hood connecting to pigtail in hood junction box white to white black to black and connect green ground wire to power supply ground wire per local codes The VEN100E 150E ventilator will require revision of some wiring in the hood receptacle box and possible modification of air discharge opening See VEN100E 150E instructions NOTE VEN150E requires a 20...

Page 3: ...NT OF HOOD A HOOD MODEL PER36 PER42 PER54 DIM A 20 1 2 26 1 2 38 1 2 53 1 2 29 1 2 23 1 2 DIM A PSL66 PSL42 PSL36 HOOD MODEL PSL54 41 1 2 KNOCK OUTS COVER HOOD TOP HOOD WIRING MOUNTING ACCESS SCREW REMOVE APPROPRIATE KNOCK OUTS AND CONNECT WIRING ACCORDING TO HOOD AND BLOWER INSTALLATION INSTRUCTIONS CAUTION ALWAYS INSTALL RECEPTACLE BOX COVER RECEPTACLE BOX COVER COVER IS PACKED WITH FILTERS ...

Page 4: ...18 B 8 18 W 10 18 B 7 18 W 18 B 18 BL 18 R 18 W 5 18 W 25 18 B 12 18 W 13 18 G 11 18 BL 3 18 B 2 18 R 4 BLOWER MOTOR ROTARY 3 SPD SWITCH BOX RECEPTACLE RECEPTACLE PLUG POWER SUPPLY N G L1 WIRING DIAGRAM INTERNAL BLOWER LIGHTING A B 1 2 3 SWITCH LIGHT I I I I I I 1 2 3 4 5 6 18 W 5 Rev B ...

Reviews: