4
2.
Electric specifications and
limitations
2.1 Operation ranges
Property
Min
Typ
Max
Unit
Notes
Motor supply voltage
(model 08020)
12
-
80
VDC
Optimal U=rated+10..20%
Motor supply voltage
(model 16035 without using
braking circuit)
12
-
80
VDC
Optimal U=rated+10..20%
Motor supply voltage
(model 16035 with using
braking circuit)
12
-
160
VDC
1.) Optimal U=rated+10..20%
2.) >160VDC input Votlage
may cause permanent dam-
age to the device!
Motor current
(model 08020)
0
-
20
A
Limited by drive at software
set threshold, maximum at
20A
Motor current
(model 16035)
0
-
35
A
Limited by drive at software
set threshold, maximum at
35A
Logic supply voltage
11.5
12
14
VDC
>20VDC input Voltage may
cause permanent damage
to the device!
Logic supply current
150
200
250
mA
Operating temperature
0
65
°C
Automatic shutdown at
65°C
Opto-isolator input Voltage
3
-
-
Use external series re-
sistor in case of input
Voltage>5VDC
For 12V input use 1kOhm
For 24V input use 2.2kOhm