User’s Manual 

 

Page 5 

 

4.0 

REQUIREMENTS  

     4.1     Power Requirements  

Regulated 24VDC@200mA   is required to power this board.  

 

WARNING 

 

 

Check the polarity and voltage of the external power source and connect the 24VDC and 
GND. Overvoltage or reverse-polarity power applied to these terminals can cause damage 
to the board, and/or the power source.  
 

 

5.0 

TERMINAL POWER  

  

Regulated 12 or +24VDC@200mA is required to power this board.   

 

 

6.0 

ACTIVATING THE BOARD  

  

Fault monitoring starts when the board is active.  When the board is active the relay is 

activated and the green LED is on. 

 

  

Two conditions must be met to activate the system and start monitoring for a fault: 

 

  

1.

  At least one axis is receiving an active enable signal from the ACORN board or 

the jumper is set not to monitor the ACORN enable signals. 

 

Summary of Contents for C86ACCP6

Page 1: ...User s Manual Page 1 USER S MANUAL VER 1 C86ACCP6 CleartPath Connector Board for the AcornSix 6 axis CNC controller Rev 1 NOVEMBER 2022...

Page 2: ...REMENTS 5 4 1 Power Requirements 5 5 0 TERMINAL POWER 5 6 0 ACTIVATING THE BOARD 5 6 1 Operation Sequence 6 7 0 JUMPER TO SELECT THE ACTIVE AXIS 7 8 0 JUMPER TO SELECT THE ENABLE 7 9 0 LED INDICATOR 8...

Page 3: ...d Direction signals from axis X or Y to allow wiring an additional axis using the same signals The board can be activated and start monitoring for a driver fault using the axis enable or NO_FAULT sign...

Page 4: ...User s Manual Page 4 3 0 BOARD DESCRIPTION...

Page 5: ...amage to the board and or the power source 5 0 TERMINAL POWER Regulated 12 or 24VDC 200mA is required to power this board 6 0 ACTIVATING THE BOARD Fault monitoring starts when the board is active When...

Page 6: ...nals It could also be hardwired to be permanently active if both inputs are jumped 6 1 Operation Sequence 1 Once the board gets enabled it will take 5 seconds in order for it to start monitoring for a...

Page 7: ...as shown in the image 1 2 OFF Note Set the jumper to ON for connected axis and off if no drivers are connected 8 0 JUMPER TO SELECT THE ENABLE Use Software Enable to keep the driver active only while...

Page 8: ...User s Manual Page 8 9 0 LED INDICATOR When Status LED Green LED lights it indicates that the system is enabled 9 1 INDICATOR FAULT DETECTION...

Page 9: ...ASSIGNMENTS PIN COLOR NAME CLEAR PATH PLUGGABLE TERMINAL C86ACCP FUNCTION 1 GRN HLFB HLFB ALARM 2 BLK INPUT B B STEP 3 WHT INPUT A A DIRECTION 4 BLU ENABLE EN ENABLE 5 RED HLFB GND GND 6 YEL INPUT B...

Page 10: ...User s Manual Page 10 11 0 WIRING EXAMPLE PLUGGABLE TERMINAL...

Page 11: ...User s Manual Page 11 12 0 WIRING EXAMPLE...

Page 12: ...machines Neither DUNCAN USA LLC nor Arturo Duncan is liable for any accidents resulting from the improper use of these devices This product is not a fail safe device and it should not be used in life...

Reviews: