Page 1: ...User s Manual Page 1 USER S MANUAL VER 1 C86ACCP6 CleartPath Connector Board for the AcornSix 6 axis CNC controller Rev 1 NOVEMBER 2022...

Page 2: ...REMENTS 5 4 1 Power Requirements 5 5 0 TERMINAL POWER 5 6 0 ACTIVATING THE BOARD 5 6 1 Operation Sequence 6 7 0 JUMPER TO SELECT THE ACTIVE AXIS 7 8 0 JUMPER TO SELECT THE ENABLE 7 9 0 LED INDICATOR 8...

Page 3: ...d Direction signals from axis X or Y to allow wiring an additional axis using the same signals The board can be activated and start monitoring for a driver fault using the axis enable or NO_FAULT sign...

Page 4: ...User s Manual Page 4 3 0 BOARD DESCRIPTION...

Page 5: ...amage to the board and or the power source 5 0 TERMINAL POWER Regulated 12 or 24VDC 200mA is required to power this board 6 0 ACTIVATING THE BOARD Fault monitoring starts when the board is active When...

Page 6: ...nals It could also be hardwired to be permanently active if both inputs are jumped 6 1 Operation Sequence 1 Once the board gets enabled it will take 5 seconds in order for it to start monitoring for a...

Page 7: ...as shown in the image 1 2 OFF Note Set the jumper to ON for connected axis and off if no drivers are connected 8 0 JUMPER TO SELECT THE ENABLE Use Software Enable to keep the driver active only while...

Page 8: ...User s Manual Page 8 9 0 LED INDICATOR When Status LED Green LED lights it indicates that the system is enabled 9 1 INDICATOR FAULT DETECTION...

Page 9: ...ASSIGNMENTS PIN COLOR NAME CLEAR PATH PLUGGABLE TERMINAL C86ACCP FUNCTION 1 GRN HLFB HLFB ALARM 2 BLK INPUT B B STEP 3 WHT INPUT A A DIRECTION 4 BLU ENABLE EN ENABLE 5 RED HLFB GND GND 6 YEL INPUT B...

Page 10: ...User s Manual Page 10 11 0 WIRING EXAMPLE PLUGGABLE TERMINAL...