7
4.9 Dry Contact Signal
(Optional)
There is one dry contact (3A250VAC) available on the rear panel. It could be used to deliver signal to
external device when battery reaches warning level.
Unit Status State
NC & C
C & NO
Power off
Unit is off and no output is powered
Open Close
Power on
Battery voltage <Setting the voltage in program 12
Close
Open
Battery voltage >Setting the voltage in program 13
Open
Close
4.10 Bluetooth Communication
(Optional)
This unit is equipped with a Bluetooth transmitter. Download “RevoMonitor” APP from Google Play .
Once the APP is download, you may connect “RevoMonitor” APP to your inverter with the pairing
password “1234”. The communication distance is roughly 6 ~ 7 meters.
Note:
1.the following date are for reference only.
2.Bluetooth APP only supports Android phone users.