SK350 Operator’s Manual
Service - 55
50 Hour
CMW
Check Drive Belt
Check drive belt every 50 hours. Adjust belt tension if necessary. Replace if cracked, stretched, or badly
worn. Tensioner should be set at 2.5-3 increment marks.
To adjust:
1.
Loosen bolt on tensioner (1).
2.
Apply wrench to large nut (2).
3.
Tighten tensioner until the fixed bar on the base is
lined up with the third bar on the tensioner arm as
shown (3).
IMPORTANT: See belt changing procedure on page 62.
Summary of Contents for Ditch Witch SK350
Page 1: ...SK350 Operator s Manual Issue 3 1 Original Instruction CMW...
Page 9: ...Contents 8 SK300 Operator s Manual CMW...
Page 19: ...Safety 18 SK350 Operator s Manual Emergency Procedures CMW...
Page 49: ...Service 48 SK350 Operator s Manual Overview CMW Overview...
Page 71: ...Specifications 70 SK350 Operator s Manual Basic Unit CMW...
Page 74: ......
Page 75: ......
Page 76: ...SK350 Operator s Manual Service Record 75 CMW Service Record Service Performed Date Hours...
Page 77: ...CMW Service Record 76 SK350 Operator s Manual Service Performed Date Hours...