10.5 Operation of timer M
10.5.1
Enter the capture function
This is a function of measuring the width and period of an external signal. Triggered with the external signal of
the TMIOji pins (i=0, 1, j=A, B, C, D), will be The contents of the TMi register (counter) are transferred to the TMGRji
register (input capture). Because the TMIOji pin and the TMGRji register are used in combination, they can be pin-
selected as input capture functions, or other modes and functions.
The block diagram and running example of the input capture function are shown in Figures 10-46 and 10-47,
respectively, and the specifications of the input capture function are shown in Table 10-12.