SECTION 1 Installation

b. For other circulation systems, CMP provides a wide range of 

installation kits. Contact Customer Service for assistance. 

3B.  Plumbing - Ozone Generator

a. Connect ozone compatible tubing (1/4” internal diameter) to the 

check valve on the DEL Ozone Spa XO3.

b. Run tubing to the ozone injector or appropriate vacuum source.

i.  If the ozone generator is mounted above the water line, 

tubing may be run directly to the vacuum source.

ii.  If ozone generator is mounted below the water line, run 

tubing to a point above the water line and back down to the 

vacuum source.

c.  Secure all tubing connections with hose clamps. 

4.  Electrical

a. Verify that there is no power to the spa and connect the DEL 

Ozone Spa XO3 cord into the mating connector(s) on the spa 

control box.

b. Where possible, route the DEL Ozone Spa XO3 power cord away 

from other electrical lines. Avoid routing the power cord parallel 

to any low-voltage signal wires.

 

5.  Operation

a. With the spa filled to the proper level, run the spa controller 

through several cycles.

i.  Verify that the green light on the DEL Ozone Spa XO3 turns 

on and off as required by the controller.

ii.  Verify that gas is flowing into the injector (there should be no 

water in the tubing and very small bubbles at the return).

iii. Verify that water does not push past the check valve during 

any spa cycle.

iv. Check for and correct any leaks in the ozone tubing.

Summary of Contents for DEL OZONE XO3

Page 1: ...ON READ AND FOLLOW ALL INSTRUCTIONS Save these instructions Leave manual with homeowner after installation Improper installation adjustment alteration service or lack of maintenance can cause injury o...

Page 2: ...XO3 must be mounted indoors or sheltered under a cover from natural elements rain sun sprinklers Mount the DEL Ozone Spa XO3 so that it is inaccessible to anyone in the spa NOTICE Plastic ozone supply...

Page 3: ...ECTION 2 Maintenance 6 System Maintenance 3 SUPPORT 6 DIAGRAMS SHOWN IN THESE INSTRUCTIONS page 2 DEL OZONE TYPICAL MIXING SYSTEM page 5 DEL OZONE SPA XO3 MOUNTING CONNECTIONS TABLE OF CONTENTS Covere...

Page 4: ...Ozone Spa XO3 must be mounted horizontally with ozone tubing connection pointing down Use both mounting flanges c Mount using the tabs are provided on the DEL Ozone Spa XO3 spaced 3 8 inches 96 mm hor...

Page 5: ...connections with hose clamps 4 Electrical a Verify that there is no power to the spa and connect the DEL Ozone Spa XO3 cord into the mating connector s on the spa control box b Where possible route th...

Page 6: ...and tubing should be replaced annually c Regularly inspect ozone supply tubing for cracks or wear Also check to make sure no water is present between the check valve and the ozone generator This indic...

Page 7: ...5 SECTION 2 Maintenance Figure 2 DEL Ozone Spa XO3 Mounting Connections Ozone Outlet Mounting Flange Connector...

Page 8: ..._________________ System Purchased From _____________________________________________ Installation Date _____________________________ Serial Number _______________________________ Model Number _______...

Page 9: ...7 NOTES...

Page 10: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 0621ab...

Reviews: