3
SECTION 1 Installation
b. For other circulation systems, CMP provides a wide range of
installation kits. Contact Customer Service for assistance.
3B. Plumbing - Ozone Generator
a. Connect ozone compatible tubing (1/4” internal diameter) to the
check valve on the DEL Ozone Spa XO3.
b. Run tubing to the ozone injector or appropriate vacuum source.
i. If the ozone generator is mounted above the water line,
tubing may be run directly to the vacuum source.
ii. If ozone generator is mounted below the water line, run
tubing to a point above the water line and back down to the
vacuum source.
c. Secure all tubing connections with hose clamps.
4. Electrical
a. Verify that there is no power to the spa and connect the DEL
Ozone Spa XO3 cord into the mating connector(s) on the spa
control box.
b. Where possible, route the DEL Ozone Spa XO3 power cord away
from other electrical lines. Avoid routing the power cord parallel
to any low-voltage signal wires.
5. Operation
a. With the spa filled to the proper level, run the spa controller
through several cycles.
i. Verify that the green light on the DEL Ozone Spa XO3 turns
on and off as required by the controller.
ii. Verify that gas is flowing into the injector (there should be no
water in the tubing and very small bubbles at the return).
iii. Verify that water does not push past the check valve during
any spa cycle.
iv. Check for and correct any leaks in the ozone tubing.