CMP DEL OZONE XO3 Installation Instructions & Product Manual Download Page 2

2

READ AND FOLLOW ALL INSTRUCTIONS

Read this manual completely before attempting installation. All permanent electrical 
connections should be made by a qualified electrician. Follow all applicable electrical codes.

DANGER

  Be sure the electrical power is shut OFF at the main circuit breaker before 

installing the DEL Ozone® Spa XO3.

NOTICE

  If the DEL Ozone® Spa XO3 electrical connection is to be attached to the spa 

controls, be sure the spa controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). 
If the DEL Ozone® Spa XO3 is connected to an independent electrical supply, then a G.F.C.I. 
must be installed between the DEL Ozone® Spa XO3 and the electrical supply. 

WARNING

To reduce the risk of electrical shock, if the power cord  

is damaged, replace the entire unit immediately. The DEL Ozone® Spa XO3 must be located 
or fixed so that it cannot fall into the spa.

NOTICE

  The DEL Ozone® Spa XO3 must be mounted indoors or sheltered, under a 

cover, from natural elements (rain, sun, sprinklers). Mount the DEL Ozone® Spa XO3 so that it 
is inaccessible to anyone in the spa.

NOTICE

  Plastic ozone supply tubing is available with the DEL Ozone® Spa XO3. 

Never replace this tubing with metal tubing.

CAUTION

  Do not operate the DEL Ozone® Spa XO3 unless sufficient air flow is being 

drawn through the unit.

WARNING

Short term inhalation of high concentrations of ozone and long term 

inhalations of low concentrations of ozone can cause harmful physiological effects. Do not 
inhale ozone gas produced by this device.

NOTICE

  This appliance can be used by children aged from 8 years and above and 

persons with reduced physical, sensory or mental capabilities or lack of experience and 
knowledge if they have been given supervision or instruction concerning use of the appliance 
in a safe way and understand the hazards involved. Children shall not play with the appliance. 
Cleaning and user maintenance shall not be made by children without supervision.

SAVE THESE INSTRUCTIONS!

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for DEL OZONE XO3

Page 1: ...ON READ AND FOLLOW ALL INSTRUCTIONS Save these instructions Leave manual with homeowner after installation Improper installation adjustment alteration service or lack of maintenance can cause injury o...

Page 2: ...XO3 must be mounted indoors or sheltered under a cover from natural elements rain sun sprinklers Mount the DEL Ozone Spa XO3 so that it is inaccessible to anyone in the spa NOTICE Plastic ozone supply...

Page 3: ...ECTION 2 Maintenance 6 System Maintenance 3 SUPPORT 6 DIAGRAMS SHOWN IN THESE INSTRUCTIONS page 2 DEL OZONE TYPICAL MIXING SYSTEM page 5 DEL OZONE SPA XO3 MOUNTING CONNECTIONS TABLE OF CONTENTS Covere...

Page 4: ...Ozone Spa XO3 must be mounted horizontally with ozone tubing connection pointing down Use both mounting flanges c Mount using the tabs are provided on the DEL Ozone Spa XO3 spaced 3 8 inches 96 mm hor...

Page 5: ...connections with hose clamps 4 Electrical a Verify that there is no power to the spa and connect the DEL Ozone Spa XO3 cord into the mating connector s on the spa control box b Where possible route th...

Page 6: ...and tubing should be replaced annually c Regularly inspect ozone supply tubing for cracks or wear Also check to make sure no water is present between the check valve and the ozone generator This indic...

Page 7: ...5 SECTION 2 Maintenance Figure 2 DEL Ozone Spa XO3 Mounting Connections Ozone Outlet Mounting Flange Connector...

Page 8: ..._________________ System Purchased From _____________________________________________ Installation Date _____________________________ Serial Number _______________________________ Model Number _______...

Page 9: ...7 NOTES...

Page 10: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 0621ab...