5.2.4. 

System info

Hold the lower button for three seconds to view the system info.

The system info shows the current firmware version.

5.2.5. 

Factory reset

Press and hold both buttons in order to execute a factory reset. All settings will be reset to 

default.

5.2.6. 

Status LEDs

The status LED of the lower button indicates the current radio status.

LED (Lower button) 

Status

Solid green

Ready, client logged on

Yellow/red flashing

Selected channel used by another device

Green/red flashing

No device connected, wireless or hardwired

Solid red

Camin initializing / hardware fault

Red flashing

Update

Summary of Contents for cPRO camin

Page 1: ...page 1 of 30 All content 2019 cmotion GmbH All specifications are subject to change without further notice http www cmotion eu v2 1 December 2019 Software Release Package v3 0 cPRO camin User Guide...

Page 2: ...or written consent of cmotion GmbH Specifications are subject to change without notice Errors ommissions and modifications excepted For further assistance cmotion GmbH Wiedner Hauptstra e 135 B3 1050...

Page 3: ...tes etc for the most up to date specifications Not all products and or types are available in every country Please check with a cmotion sales representative for availability and additional information...

Page 4: ...tup 11 5 2 1 Radio channels 11 5 2 2 Command mode 11 5 2 3 Region settings 12 5 2 4 System info 13 5 2 5 Factory reset 13 5 2 6 Status LEDs 13 6 cPRO camin preparation 14 6 1 cPRO camin bracket 14 6 2...

Page 5: ...o change without further notice http www cmotion eu 10 Appendix 21 10 1 Antenna connector 21 10 2 Specifications 21 10 3 Dimensions and weight 22 10 4 Pinouts 23 10 5 Part numbers 24 10 6 Cleaning and...

Page 6: ...icate different risk levels Danger DANGER indicates an imminent hazardous situation which if not avoided will result in death or serious injury Warning WARNING indicates a potentially hazardous situat...

Page 7: ...ays unplug the cable by gripping the plug not the cable Never try to repair All repair work should be done by a qualified cmotion Service Center Never remove or deactivate any safety equipment incl wa...

Page 8: ...lusively for use on professional camera setups 3 Scope of delivery and warranty NOTICE Product and packaging contain recyclable materials Always store ship and dispose of according to local regulation...

Page 9: ...io channels Using the LBUS interface the system can be expanded with up to three additional cforce motors while the new CAM connector provides a versatile interface for power supply and run stop contr...

Page 10: ...he CAM interface offers a versitile interface for camera control There are camera interface cables which depending on the camera offer start stop control and record feedback camera status tally and co...

Page 11: ...turns off after 3 seconds 5 2 Setup 5 2 1 Radio channels The RF menu lets you select the radio channel Press the lower or upper button momentarily to enter the radio menu The upper button allows you...

Page 12: ...conds to enable the function Command mode is available from software version 3 0 For further information on how to use command mode please refer to section 6 5 Setting up the cPRO camin s command mode...

Page 13: ...ion 5 2 5 Factory reset Press and hold both buttons in order to execute a factory reset All settings will be reset to default 5 2 6 Status LEDs The status LED of the lower button indicates the current...

Page 14: ...0 UNC or 3 4 16 UNC mounting insert depending on the mounting options on your camera 2 Match the registraion marks of the insert and the cPRO camin bracket and snap in the insert accordingly The inser...

Page 15: ...RO camin basic set For this K2 0006176 cforce mini clamp console 19 15mm including K2 0006175 cforce mini clamp insert 19 15mm is required and needs to be ordered seperately Mounting to 15 mm rods 1 S...

Page 16: ...ew counter clockwise 3 Remove the 19 15mm clamp insert 4 Attach the CLM 4 Clamp Insert 5 8 K2 72115 0 to the 5 8 rod 5 Attach the clamp console around the clamp insert on the rod 6 Close the clamp con...

Page 17: ...cPRO camin please refer to the cPRO hand unit user manual Once both units are set to the same radio channel the two devices will connect automatically 2 If multiple hand units are used please set all...

Page 18: ...to client In order to switch between master and client simply press and hold the upper button on the cPRO camin for 3 seconds Then select master or client with the up down buttons and wait for 5 secon...

Page 19: ...PRO motor master on the camera side In order to extend the RF range you need to create two independent transmission paths Set the cPRO camin master to the same radio channel as the wireless device e g...

Page 20: ...PANAVISION using aditional CAM interface cables 8 Software update The cPRO camin can be updated from the cPRO hand unit via USB through its LBUS interface To keep your cPRO camin up to date you may ne...

Page 21: ...is left open 10 2 Specifications Electrical data Temperature range 20 to 50 C 4 to 122 F Supply voltage 10 5 34 V Radio system The cPRO camin contains a radio unit that enables wireless lens control...

Page 22: ...30 All content 2019 cmotion GmbH All specifications are subject to change without further notice http www cmotion eu 10 3 Dimensions and weight Dimensions Weight Weight of cPRO camin 77 g 3oz includi...

Page 23: ...ther notice http www cmotion eu 10 4 Pinouts The cPRO motor contains one LBUS connector Lemo 4 pin and one CAM connector Lemo 7 pin LBUS connector 1 GND 2 CAN L 3 V BAT 4 CAN H CAM connector 1 CAM lf1...

Page 24: ...0013627 Dipole Reverse SMA Proant K2 0001996 Dipole Reverse SMA Nearson O5 20112 0 Dipole Reverse SMA The following accessories are compatible with the cPRO motor K2 0001996 swivel antenna for SMC 1...

Page 25: ...p LANC D Tap Connects cPRO motor and camin to LANC connector e g Canon C300 C500 and D Tap power source Provides camera RUN STOP function and tally on cPRO hand unit K2 0015758 Cable CAM 7p RED CTRL D...

Page 26: ...information and camera control on cPRO hand unit SONY camera control license required K2 0015760 Cable CAM 7p LBUS Connects cPRO motor and camin to LBUS devices or LBUS power source Provides power to...

Page 27: ...n exposed to salty air wipe down the external components with a damp but well wrung cloth Do not use cleaning agents that contain organic solvents to clean the button panels or display For stubborn ma...

Page 28: ...1096 2 camadeus Film Technologies Inc 314 N Victory Blvd Burbank CA 91502 http www camadeus com contact camadeus com Service Hotline 1 321 345 6765 3 ARRI China Beijing Co Ltd China Chaowai SOHO Suite...

Page 29: ...gle market european standards harmonised standards index_ en htm FCC Class A Statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to...

Page 30: ...Japan MIC Statement Complies with Ministry of Internal Affairs and Communications notification Article 88 Annex 43 Radio Module The cPRO camin contains the following radio module FCC ID Y7N EMIP400 I...

Reviews: