To obtain coffee of satisfactory  uality, it is important for the water used to have a value of  -   F (French degrees). If the water hardness is 
greater, the use of a softener is advisable.
Avoid using the softener if the water hardness is less than    F.
If the taste of chlorine in the water is especially noticeable, a special filter should be installed.
It is not advisable to keep large amounts of coffee beans, nor to grind large amounts of coffee. Set aside the amount in the container and if 
possible use it before the end of the day. Do not purchase pre-ground coffee as it expires in a short amount of time.
After the machine has not been used for a relatively long period of time ( -  hours) cycle through a few dry runs.
Always carry out periodic cleaning and maintenance.

I T O

A ARD

This chapter describes possible hazards for the user if  the specific safety standards  described  in this booklet are not adhered to.

T

If this is not done, the appliance can be a source of dangerous electrical discharges in that it is no longer able to  discharge electricty to 
earth.

D

The use of pressurized water directly on the machine can seriously damage electrical appliances.  ever use water jets to wash any part of 
the appliance.

During use, the steam nozzles and hot water may overheat, thus becoming a source of danger.    andle such parts carefully.  ever direct 
steam or hot water jets directly on parts of the body.

D

Before carrying out any intervention on the machine you must turn it off by means of the main network switch or better yet, disconnecting the 
connection terminals in the network.  ever remove any body panel when the machine is supplied with electrical power.

N

All work regarding the hydraulic system and the relative boiler are to be avoided when there is still water and pressure in the system.  ou 
must therefore empty it beforehand, closing the mains cock and dry-running the delivery group  for a short time. Switch off the machine and 
open all the steam and water cocks and taps.  ith the pressure zero, completely empty the boiler, unscrewing the special pipe fitting situated 
on the lower part of it.
If the above procedure is not correctly carried out,  opening  any part of the hydraulic system can cause a sudden outlet of overheated water 
under pressure.

ever lower the lever if there is no coffee in the filter, or if the filter holder is not installed on the group  the sudden upwards movement of the 

lever may damage the appliance and injure individuals. 

G

Periodically check for gas leaks in the system by applying a soapy solution to the ducts.
For safety reasons, close the gas heating system when the machine is not in use (at night or during hours of closure)

U

This espresso coffee machine is an appliance exclusively for professional use. Any other type of use is considered wrong and therefore dan-
gerous.  ever allow children or incapable persons to use the machine.

on-observance of the above-described standards can cause serious damage to people or animals.
ever work on the electronic apparatus when the machine is still supplied with electrical energy.

Shut down the machine completely by unplugging it from the mains before carrying out any operation.

Summary of Contents for Espresso Coffee Machine

Page 1: ...ENGLISH ESPRESSO COFFEE MACHINE USE AND MAINTENANCE MANUAL Instructions for the user Via Condotti Bardini 1 31058 SUSEGANA TV ITALY Tel 39 0438 6615 Fax 39 0438 60657 www cmaspa com cma cmaspa com R...

Page 2: ......

Page 3: ...TENSIONE 73 23 CEE al que se re ere esta declaraci n es conforme con lo que disponen las siguientes DIRECTIVAS CEE 98 37 CE 89 336 CEE 97 23 CE DIRECTIVA BAJO VOLTAJE 73 23 CEE auquel se r f re cette...

Page 4: ...Review Rev 04 05 2005 General review...

Page 5: ...MA VERSION 11 5 2 AEP SMSA VERSION 11 5 3 JUNIOR VERSION 11 5 4 AEAP SMAT VERSION 12 5 5 SAE SME VERSION 13 6 PREPARATION OF HOT DRINKS 14 6 1 DISPENSING HOT WATER MANUALLY 14 6 2 DISPENSING HOT WATER...

Page 6: ...values indicated on the data plate correspond to those in the electrical network The data plate is located on the front or side panel of the machine The installation must be performed by ualified and...

Page 7: ...uries During operation the steam and hot water outlets are very hot handle them very carefully and only in the places specified for that pur pose Place cups upon the cup heater plateau especially desi...

Page 8: ...filter holder Adjustable foot ot water dispensing spout as burner viewing window if included cup filter holder as safety if included as ignition push button if included achine main switch commutator u...

Page 9: ...nd of the softener Turn the switch to position electrical power supplied to the pump for automatic boiler filling and machine services and wait for the boiler to be automatically filled with water Tur...

Page 10: ...ore fixing the handle to the socket of the brewing group Follow the instructions provided by the manufacturer of the grinder doser GA ATING Turn the switch A round to position pen the gas cock placed...

Page 11: ...e cup under the dispensing spout press the desired dose key wait for dispensing to finish D comes on to stop coffee delivery in advance press the delivery key again or press the ST P key if the push b...

Page 12: ...of coffee in the cup has been reached press the ST P PR key or the key of the dose being programmed to stop delivery and memorize the new value the duration of the dose of coffee is calculated in sec...

Page 13: ...keys upon completion of programming place the programming lever back in the FF position In some models the programming lever has been eliminated because to access program and it is enough to press the...

Page 14: ...programming place the programming lever back in the FF position DI N ING T A To dispense steam turn the tap knob counter clockwise the amount of steam which comes out of the steam nozzle will be propo...

Page 15: ...to things people and animals D The removal of the coffee form the container is done by activating the dispenser lever placed in the lower central part The coffee remaining in the container can be heat...

Page 16: ...or resin residue from the gasket located on the lid Put the lid back in place by screwing the knob down securely and move the lever back from right to left et the salt water drain from the small tube...

Page 17: ...am nozzles and clean them monthly clearing out the exit holes with a small needle D A A The cleaning of the internal parts of the delivery groups is to be performed weekly in the following manner repl...

Page 18: ...t be replaced when there is too much powder in the ground coffee the grinders have a life cycle of approximately kg of coffee Perform the following steps on a weekly basis perform regeneration of the...

Page 19: ...the machine you must turn it off by means of the main network switch or better yet disconnecting the connection terminals in the network ever remove any body panel when the machine is supplied with e...

Page 20: ...n or has obstruction to water flow heck the sewer drain heck and restore the connection of the drain tube to the tub FF IS T D T D I R F FF IS T FAST The coffee is ground too coarsely The coffee is gr...

Page 21: ...Re uest assistance from technical service T P P F TI S B T I A APA IT T T R ST PS S DD R T T R A PR T TI TS I D T A R AD T P P IS IS WARNING If the problem is not solved turn the machine off and cont...

Page 22: ......

Page 23: ......

Page 24: ...C M A S p A Via Condotti Bardini 1 31058 SUSEGANA TV ITALY Tel 39 0438 6615 Fax 39 0438 60657 www cmaspa com cma cmaspa com Cod 02000000 Rev 04 05 2005...

Reviews: