![CMA Dishmachines CMA-181VL Owner'S Manual Download Page 4](http://html.mh-extra.com/html/cma-dishmachines/cma-181vl/cma-181vl_owners-manual_2627045004.webp)
MODEL CMA-181VL INSTALLATION & OPERATION MANUAL Rev. 1.00
Page
3
1.2.
CMA-181VL Operational Cycle
The CMA-181VL Operational Cycle (including water vapor evacuation) has a total cycle time
of three (3) minutes (180 seconds). The Timing Diagram and the steps listed below detail the
individual functions that are executed during each Operational Cycle.
Seconds:
0
10
20
30
40
50
60
70
80
90
100
110
120
Seconds:
120 130 140 150 160 170 180
1.
With the machine powered up, toggling the START switch begins a cycle.
a)
Toggling the START switch energizes both the Cam Timer motor and the Instant Start
Relay. The Instant Start Relay latches ON the power to the Cam Timer motor so that
the START switch can be released a moment after it has been toggled without the Cam
Timer motor losing power.
b)
After about 1.5 seconds the Cam Timer’s first cam—the Cam Timer Motor Cam—
latches ON the power to the Cam Timer motor and drops out the Instant Start Relay.
The Cam Timer motor continues to run for a total of 3 minutes, at which time it
switches OFF—resetting the Cam Timer—and waits for the next START command.
2.
The Cam Timer’s third cam controls the Wash Pump. The Wash Pump comes ON about 3
seconds into the Operational Cycle and continues to run for 96 seconds. This 96-second
period is the Wash Cycle.
Instant
Start Relay
Cam Timer
Motor Cam
Rinse Cycle
Cam
Wash Cycle
Cam
Drain Pump
Cam
Safe-T-
Temp Cam
Cam Timer
Fan Cam
Fill Cam