5. Customer Notice
CMA-181GW Installation Guidelines
Improper installation of this product may void the warranty on this machine. Please follow
these guidelines for recommended installation and to ensure the warranty of this model is
authorized by CMA Glasswashers.
1. Machine
Glasswasher Installation Requirements
must
2. Drain height should not exceed maximum height of 16”. Connect supplied
drain line to 3-way valve on back of machine and gravity feed to the floor
drain.
be level. Adjust leveling feet to accommodate uneven floor
surfaces.
3. Check the Pressure. Recommended pressure is between 18-20 psi.
4. Water supply to machine must be a minimum 120°F for 3minute cycle
models and 140°F for 2 minute cycle models.
5. A four-wire, (neutral, ground and two 110v lines) 220v single phase
connection is required. There is a six foot cord provided with the machine.
CMA recommends a minimum 50-amp dedicated circuit, but you should
consult your local building code requirements for proper breaker size.
1. Booster heater
Activating/Adjusting the Booster Heater
must
2. Once the booster has been connected, the thermostat should be adjusted
to maintain 180°F during the final rinse cycle. The thermostat is located on
the front of the booster tank and is accessible by removing the front panel
on the machine.
be filled with water prior to connecting the blue wire
from high limit switch. The high limit switch can be found by removing the
front panel and locating the red button on the front of the heater tank.
1. Applications utilizing automated dispensers for administering warewash
chemicals must use 110v dispenser equipment. There is a 110v power
block for installing this equipment inside the control panel.
Automatic Dispensing Equipment