ENGLISH
34
TECHNICAL MANUAL
piston gr i
or
ii
JAMMED
1.
The gear motor has
broken
2.
The rest microswitch is faulty or
the connection is interrupted
3.
Position of the rest microswitch
cam incorrect
1.
Change the gear motor
2.
Restore connection
and/or change the
rest microswitch if
necessary
3.
Enter machine
programming and,
with the test input,
position the rest
compression
insufficient
1.
Change the fuse
-
Press the key
-
Switch the machine off and then on
1.
The motor transformer protection
fuse has blown
cHECK BOILER WATER
LEVEL
2.
Open all the cocks upstream from
the machine
2.
Softener cock closed
1.
Check whether or not there is water in the
mains
1.
No water in the mains
3.
Change the
pump filter
3.
Pump filter clogged
4.
Change the
solenoid valve
filter
4.
Loading solenoid valve filter
clogged
vol. DOSER gr i
or
ii
noT COUNTING
cam properly
cause
remedy
display
2.
The rest microswitch is either
faulty or the connection is
interrupted
2.
Restore the connection
and/or change the rest
microswitch
All manuals and user guides at all-guides.com