SYMPTOM:
MACHINE IS “STICKY”,
IRREGULAR OR HARD TO MOVE
The foot pedals and handgrips are attached to
metal bars that move up and down inside C
shaped metal channels. The bars have plastic
rollers and slides that guide the bars through the
channels. Over time the lubricant in the channels
picks up dust and lint and dries out producing a
“sludge” tar like coating that prevents smooth
machine operation. Remove the tar like coating
with paint thinner on a rag and the machine will
function like brand new.
SYMPTOM:
OIL LEAK FROM HYDRAULIC
ADJUSTMENT KNOB
An oil leak from the hydraulic knob (brass knob)
indicates either a loose connection or a malfunction
in the needle valve. Tighten the nut on the needle
valve if it is loose. If leak persists the valve must
be replaced. Do not remove the defective valve
until you receive the new one.
Detailed installation
instructions will be included with the replacement
valve.
SYMPTOM:
OIL LEAK FROM RESERVOIR
ON TOP OF HYDRAULIC MOTOR
If oil leaks from the top seal between the black
plastic cap and the plastic bowl, tighten cap by
hand. If oil leaks from the threads at the base of
the accumulator, tighten by turning clockwise
with a wrench. If reservoir is physically damaged
and a replacement is required, do not remove the
reservoir until you receive a new one. The
replacement reservoir will include detailed
installation instructions. DO NOT USE THE
MACHINE UNLESS THE RESERVOIR IS AT
LEAST 3/4 FULL OF OIL.
Write down additional notes here: