15
b. Seal bars are located in the lid on larger SC Series machines and all DC Series machines.
2. Remove the screws that hold the Teflon holding strap in place. Refer to
Figure A on the next
page.
3. Remove the old Teflon cover.
4. Inspect the seal element.
a. Clean it off with lacquer thinner if needed.
b. Replace if broken or burnt badly.
Refer to the instructions under B below for
replacement
5. Install the new Teflon cover and reinstall the seal bars.
B. Replacing the Seal Element
1. Using a hex wrench loosen the screws holding the seal element and remove it
2. Install the new seal element.
Refer to Figures B & C on the next page.
a. Place the new element across the surface of the seal bar leave an excess of about 3/4” at
each end.
b. Make sure you put the tension spring back in place.
Summary of Contents for Promax SC-800
Page 18: ...16...
Page 22: ...20 5 3 PNEUMATIC DIAGRAM...
Page 23: ...21 5 4 ELECTRICAL DIAGRAM...
Page 25: ...6 1 BODY 23 SC80100000 Body Diagram...
Page 27: ...6 2 1 WORKING BED LR 25 Cushion Bar Set Working Bed Diagram Top...
Page 28: ...6 2 1 WORKING BED LR 26 Working Bed Diagram Bottom...
Page 31: ...6 2 2 WORKING BED FB 29 Cushion Bar Set Working Bed Diagram Top...
Page 32: ...6 2 2 WORKING BED FB 30 Working Bed Diagram Bottom...
Page 35: ...6 3 1 LID DIAGRAM LR 33 SC80300A00 Lid Diagram...
Page 37: ...6 3 2 LID DIAGRAM FB 35 SC80310000 Lid Diagram...
Page 39: ...6 4 SEALING BAR STANDARD DIAGRAM 37 SC80320A00 Sealing Bar Standard Diagram...
Page 41: ...6 4 SEALING BAR STANDARD DIAGRAM 39 SC80374A00 Sealing Bar Standard Diagram...
Page 43: ...6 5 ELECTRICAL BOX 41...